Gas Flow Meter SoC

MAX35104ETL+T 数据手册

 浏览型号MAX35104ETL+T的Datasheet PDF文件第2页浏览型号MAX35104ETL+T的Datasheet PDF文件第3页浏览型号MAX35104ETL+T的Datasheet PDF文件第4页浏览型号MAX35104ETL+T的Datasheet PDF文件第5页浏览型号MAX35104ETL+T的Datasheet PDF文件第6页浏览型号MAX35104ETL+T的Datasheet PDF文件第7页 
EVALUATION KIT AVAILABLE  
MAX35104  
Gas Flow Meter SoC  
General Description  
Benefits and Features  
High Accuracy Flow Measurement for Billing and  
The MAX35104 is a gas flow meter system-on-chip (SoC)  
targeted as an analog front-end solution for the ultrasonic  
gas meter and medical ventilator markets. With a time  
measurement accuracy of 700ps and automatic differen-  
tial time of flight (TOF), the device makes for simplified  
computation of gaseous flow.  
Leak Detection  
• Time-to-Digital Accuracy Down to 700ps  
Measurement Range Up to 8ms  
• 2 Channels: Single-Stop Channel  
High Accuracy Temperature Measurement for Precise  
Flow Calculations  
Power consumption is the lowest available with ultra-low  
62µA time-of-flight measurement and 125nA duty-cycled  
temperature measurement. Multi-hit (up to six per wave)  
capability with stop-enable windowing allows the device to  
be fine-tuned for the application. Internal analog switches,  
a configurable three-stage integrated operational ampli-  
fier chain amplifier, and an ultra-low input offset compara-  
tor provide the analog interface and control for a minimal  
electrical bill of material solution. A programmable high-  
voltage (up to 30V) pulse launcher provides up to 19dB of  
transducer launch amplitude adjustment to compensate  
for transducer aging and temperature, pressure, humidity  
affects. Early edge detection ensures measurements are  
made with consistent wave patterns to greatly improve  
accuracy and eliminate erroneous measurements. Built-in  
arithmetic logic unit provides TOF difference measure-  
ments and programmable receiver hit accumulators to  
minimize the host microprocessor access. For tempera-  
ture measurement, the device supports a single 2-wire  
PT1000 platinum resistive temperature detector (RTD) or  
NTC thermistor. A simple 4-wire SPI interface allows any  
microcontroller to effectively configure the device for its  
intended measurement.  
• One 2-Wire Sensor: PT1000, PT500 RTD, and  
Thermistor Support  
Maximizes Battery Life with Low Device and Overall  
System Power  
• Ultra-Low 62µA TOF Measurement and 125nA  
Duty-Cycled Temperature Measurement  
• Event Timing Mode with Randomizer Reduces  
Host μC Overhead to Minimize System Power  
Consumption  
• 2.3V to 3.6V Single-Supply Operation  
High Integration Solution Minimizes Parts Count and  
Reduces BOM Cost  
• Built-In Real-Time Clock  
• Small, 5mm x 5mm, 40-Pin TQFN Package  
• -40°C to +85°C Operation  
Ordering Information appears at end of data sheet.  
Applications  
Ultrasonic Gas Meters  
Medical Ventilators  
19-8501; Rev 3; 12/17  

与MAX35104ETL+T相关器件

型号 品牌 获取价格 描述 数据表
MAX3510EEP MAXIM

获取价格

Upstream CATV Amplifier
MAX3510EEP ROCHESTER

获取价格

5MHz - 65MHz RF/MICROWAVE NARROW BAND LOW POWER AMPLIFIER, QSOP-20
MAX3510EEP+ MAXIM

获取价格

Upstream CATV Amplifier
MAX3510EEP+T MAXIM

获取价格

Narrow Band Low Power Amplifier, 5MHz Min, 65MHz Max, 1 Func, QSOP-20
MAX3510EEP-T MAXIM

获取价格

Narrow Band Low Power Amplifier, 5MHz Min, 65MHz Max, 1 Func, QSOP-20
MAX3510EEP-T ROCHESTER

获取价格

5MHz - 65MHz RF/MICROWAVE NARROW BAND LOW POWER AMPLIFIER, QSOP-20
MAX3510EVKIT MAXIM

获取价格

Evaluation Kit for the MAX3510
MAX3514 MAXIM

获取价格

Upstream CATV Amplifiers
MAX3514EEP MAXIM

获取价格

Upstream CATV Amplifiers
MAX3514EEP+ ROCHESTER

获取价格

5MHz - 65MHz RF/MICROWAVE NARROW BAND MEDIUM POWER AMPLIFIER, LEAD FREE, QSOP-20