Transformer Driver for
Isolated RS-485 Interface
ABSOLUTE MAXIMUM RATINGS
Supply Voltage (V ) ...............................................-0.3V to +7V
Operating Temperature Ranges
CC
Control Input Voltages (SD, FS) .................-0.3V to (V
+ 0.3V)
MAX253C_ _ ........................................................0°C to +70°C
MAX253E_ _ .....................................................-40°C to +85°C
MAX253MJA...................................................-55°C to +125°C
Junction Temperatures
CC
Output Switch Voltage (D1, D2).............................................12V
Peak Output Switch Current (D1, D2)......................................1A
Average Output Switch Current (D1, D2) .........................200mA
Continuous Power Dissipation (T = +70°C)
MAX253C_ _/E_ _..........................................................+150°C
MAX253MJA .................................................................+175°C
Storage Temperature Range.............................-65°C to +160°C
Lead Temperature (soldering, 10s) .................................+300°C
Soldering Temperature (reflow)
A
Plastic DIP (derate 9.09mW/°C above +70°C) .............727mW
SO (derate 5.88mW/°C above +70°C)..........................471mW
µMAX (derate 4.10mW/°C above +70°C) .....................330mW
CERDIP (derate 8.00mW/°C above +70°C)..................640mW
MAX253
PDIP, SO, µMAX lead(Pb)-free .....................................+260°C
PDIP, SO, µMAX, CERDIP containing lead(Pb)............+240°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(V
CC
= 5V 10%, T = T
to T
, unless otherwise noted. Typical values are at T = +25°C.)
MAX A
A
MIN
PARAMETER
Switch On-Resistance
CONDITIONS
MIN
TYP
1.5
MAX
4.0
UNITS
Ω
D1, D2; 100mA
FS = V or open
250
150
350
200
0.45
0.4
500
300
5.0
CC
Switch Frequency
kHz
V
FS
= 0V
Operating Supply Current (Note 1)
Shutdown Supply Current (Note 2)
No load, V = 0V, FS low
mA
µA
V
SD
SD = V
High
CC
2.4
2.4
Shutdown Input Threshold
Shutdown Input Leakage Current
FS Input Threshold
Low
0.8
µA
pA
10
High
Low
V
0.8
50
V
FS
= 0V
µA
pA
V
FS Input Leakage Current
Start-Up Voltage
FS = V
10
CC
2.5
2.2
Note 1: Operating supply current is the current used by the MAX253 only, not including load current.
Note 2: Shutdown supply current includes output switch-leakage currents.
2
_______________________________________________________________________________________