030/031 AS
Aluminum Capacitors
Axial Standard
Vishay BCcomponents
Table 5
TEST PROCEDURES AND REQUIREMENTS
TEST
PROCEDURE
(quick reference)
REQUIREMENTS
NAME OF TEST
REFERENCE
Case Ø D x L = 3.3 x 11 mm
Endurance
Useful life
IEC 384-4/
EN130300
subclause 4.13
T
amb = 85 °C ; UR applied;
ΔC/C: 20 %
1000 hours
tan δ ≤ 2 x spec. limit
Z ≤ 3 x spec. limit
IL ≤ spec. limit
ΔC/C: 50 %
CECC 30301
Tamb = 85 °C; UR and IR applied;
subclause 1.8.1
1500 hours
tan δ ≤ 3 x spec. limit
Z ≤ 3 x spec. limit
IL ≤ spec. limit
no short or open circuit
total failure percentage: ≤ 3 %
Shelf life
IEC 384-4/
Tamb = 85 °C; no voltage applied;
ΔC/C, tan δ, Z:
(storage at
EN130300
500 hours
for requirements
high temperature)
subclause 4.17
see ‘Endurance test’ above
After test: UR to be applied for 30 minutes,
24 to 48 hours before measurement
IL ≤ 2 x spec. limit
Case Ø D L = 4.5 x 10 to 10 x 25 mm
Endurance
IEC 384-4/
EN130300
subclause 4.13
T
amb = 85 °C; UR applied;
UR ≤ 6.3 V; ΔC/C: + 15/- 30 %
UR > 6.3 V; ΔC/C: 15 %
tan δ ≤ 1.3 x spec. limit
Z ≤ 2 x spec. limit
2000 hours
IL ≤ spec. limit
Useful life
CECC 30301
Tamb = 85 °C; UR and IR applied;
UR ≤ 6.3 V; ΔC/C: + 45/- 50 %
subclause 1.8.1
3000 hours
UR > 6.3 V; ΔC/C: 45 %
tan δ ≤ 3 x spec. limit
Z ≤ 3 x spec. limit
IL ≤ spec. limit
no short or open circuit
total failure percentage: ≤ 1 %
Shelf life
IEC 384-4/
Tamb = 85 °C; no voltage applied;
ΔC/C, tan δ, Z:
(storage at
EN130300
500 hours
for requirements
high temperature)
subclause 4.17
see ‘Endurance test’ above
After test: UR to be applied for 30 minutes,
24 to 48 hours before measurement
IL ≤ 2 x spec. limit
www.vishay.com
186
For technical questions contact: aluminumcaps1@vishay.com
Document Number: 28327
Revision: 15-Oct-08