LMV821 SINGLE, LMV822 DUAL, LMV824 QUAD
LOW-VOLTAGE RAIL-TO-RAIL OUTPUT OPERATIONAL AMPLIFIERS
www.ti.com
SLOS434G–FEBRUARY 2004–REVISED AUGUST 2005
Absolute Maximum Ratings(1)
over operating free-air temperature range (unless otherwise noted)
MIN
MAX
5.5
UNIT
VCC Supply voltage(2)
V
VID
VI
Differential input voltage(3)
±VCC
VCC+
Unlimited
97
V
V
Input voltage range (either input)
Duration of output short circuit (one amplifier) to ground(4)
VCC–
At or below TA = 25°C, VCC ≤ 5.5 V
8 pin
D package
14 pin
86
DBV package
DCK package
DGK package
DGV package
PW package
206
θJA
Package thermal impedance(5)(6)
252
°C/W
172
127
113
TJ
Operating virtual junction temperature
Storage temperature range
150
°C
°C
Tstg
–65
150
(1) Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating
conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values (except differential voltages and VCC specified for the measurement of IOS) are with respect to the network GND.
(3) Differential voltages are at IN+ with respect to IN–.
(4) Short circuits from outputs to VCC can cause excessive heating and eventual destruction.
(5) Maximum power dissipation is a function of TJ(max), θJA, and TA. The maximum allowable power dissipation at any allowable ambient
temperature is PD = (TJ(max) – TA)/θJA. Operating at the absolute maximum TJ of 150°C can affect reliability.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
MIN
2.5
MAX
5
UNIT
VCC Supply voltage (single-supply operation)
TA Operating free-air temperature
V
LMV8xxI
LMV8xx
–40
–40
125
85
°C
4