TOPWAY
LCD Module User Manual
LM240120HFW
3.3
AC Characteristics
3.3.1 8080 Mode System Bus Timing
VSS=0V, VDD=3.3V, TOP=25C
Item
Symbol
tas80
tah80
MIN.
5
25
225
87
87
100
75
38
25
-
TYP.
MAX.
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Address setup time (D/C)
Address hold time (D/C)
System cycle time
Read pulse width
Write pulse width
High pulse width (read)
High pulse width (write)
Data setup time
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
tcy80
tpwr80
tpww80
thpw80
thpw80
tds80
tdh80
tacc80
tod80
Data hold time
Data access time
Data output disable time
75
-
131
Note:
*1. Input signal rise/fall time should be less than 15ns .
*2. CL=100pF
*3.All timing is using 20% and 80% of VDD as the reference.
3.3.2 Reset Timing
VSS=0V, VDD=3.3V, TOP=25C
Item
Symbol
MIN.
TYP.
MAX.
Unit
Reset LOW pulse width
trw
1.3
-
-
μs
Note:
*1.All timing is using 20% and 80% of VDD as the reference.
URL: www.topwaydisplay.com
www.topwaysz.com
Document Name: LM240120HFW-Manual-Rev0.2.DOC
Page: 6 of 10