Specification for a Lowpass LC Filter
MtronPTI P/N: LF9687
3b. Survive without damage: Unit shall be capable of continuous full performance after 5 hour per axis exposure
to the vibration conditions listed in Table 11.
Table 11.
Frequency
(Hz)
PSD
X, Y , and Z‐Axis(g^2/Hz)
0.01521
10
12
0.01521
17
0.10647
23
0.10647
27
0.00608
100
150
300
400
0.00608
0.03042
0.03042
0.01521
1000
2000
0.01521
0.00304
3c. Unit when packaged for transport shall be capable of continuous full performance after repeated non‐
operating exposure (power off) to the transportation vibration levels listed in Table 111.
Table 111.
Frequency
(Hz)
PSD
X, Y , and Z‐Axis(g^2/Hz)
5
40
0.015
0.015
121
200
500
0.003
0.003
0.00015
Page 2 of 4