5秒后页面跳转
LDC15F-2-S PDF预览

LDC15F-2-S

更新时间: 2024-11-19 22:53:35
品牌 Logo 应用领域
科索 - COSEL /
页数 文件大小 规格书
6页 796K
描述
AC/DC PS (OPEN FRAME)

LDC15F-2-S 数据手册

 浏览型号LDC15F-2-S的Datasheet PDF文件第2页浏览型号LDC15F-2-S的Datasheet PDF文件第3页浏览型号LDC15F-2-S的Datasheet PDF文件第4页浏览型号LDC15F-2-S的Datasheet PDF文件第5页浏览型号LDC15F-2-S的Datasheet PDF文件第6页 
Ordering information  
AC-DC Power Supplies Open Frame/Enclosed Type  
LD  
C
15  
F
-1  
-O  
6
LDC15F  
1ꢀ  
2ꢀ  
3ꢀ  
4ꢀ  
5ꢀ  
1Series name  
R
2Multiple output  
3Output wattage  
4Universal input  
5Output voltage combina-  
tion  
6Optional *4  
C :with Coating  
G :Low leakage current  
S :with Chassis  
SN :with Chassis & cover  
Y :with Potentiometer  
MODEL  
LDC15F-1  
LDC15F-2  
(
)
( )  
+5V 2.0 Peak 3.0 A  
( )  
+15V 0.3 Peak 0.6 A  
V1  
V2  
V3  
+5V 2.0 Peak 3.0 A  
(
)
DC OUTPUT  
+12V 0.3 Peak 0.6 A  
(
)
(
)
-12V 0.2 Peak 0.3 A  
-15V 0.2 Peak 0.3 A  
SPECIFICATIONS  
MODEL  
LDC15F-1  
LDC15F-2  
VOLTAGE[V]  
CURRENT[A]  
FREQUENCY[Hz]  
AC85 - 264 1 or DC110 - 370  
f
(
)
ACIN 100V 0.4typ Io=100%  
47 - 440 or DC  
( )  
ACIN 100V 70typ Io=100%  
INPUT  
EFFICIENCY[%]  
(
(
)
)
ACIN 100V 25typ Io=100%  
INRUSH CURRENT[A]  
ACIN 200V 50typ Io=100%  
(
,
,
,
)
LEAKAGE CURRENT[mA]  
VOLTAGE[V]  
0.75max 60Hz According to UL CSA VDE and DEN-AN  
+5 +12 -12  
+5  
+15  
-15  
1
*
(
)
(
)
(
)
(
)
(
)
(
)
CURRENT[A]  
0 - 2.0 Peak 3.0 0 - 0.3 Peak 0.6 0 - 0.2 Peak 0.3 0 - 2.0 Peak 3.0 0 - 0.3 Peak 0.6 0 - 0.2 Peak 0.3  
LINE REGULATION[mV]  
LOAD REGULATION[mV]  
20max  
48max  
48max  
20max  
60max  
60max  
100max  
100max  
140max  
120max  
160max  
50max  
120max  
120max  
160max  
150max  
180max  
350max  
420max  
xx  
120max  
120max  
160max  
150max  
180max  
350max  
420max  
xx  
100max  
100max  
140max  
120max  
160max  
50max  
150max  
120max  
160max  
150max  
180max  
350max  
420max  
xx  
150max  
120max  
160max  
150max  
180max  
350max  
420max  
xx  
2
2
2
2
*
*
*
*
0
to +50  
C
RIPPLE[mVp-p]  
-10 - 0  
C
0
to +50  
C
RIPPLE NOISE[mVp-p]  
OUTPUT  
-10 - 0  
C
0 to +50  
C
TEMPERATURE REGULATION[mV]  
-10 to +50 60max  
60max  
20max  
C
3
*
DRIFT[mV]  
20max  
(
,
)
START-UP TIME[ms]  
HOLD-UP TIME[ms]  
100max ACIN 85V Io=100%  
),  
(
,
(
,
)
,
(
,
)
10typ ACIN 85V Io=100% 20typ ACIN 100V Io=100% 100typ ACIN 200V Io=100%  
OUTPUT VOLTAGE ADJUSTMENT RANGE[V] Fixed  
Fixed  
11.4 to 12.6  
Fixed  
-11.4 to -12.6  
Fixed  
4.9 to 5.3  
Fixed  
14.25 to 15.75  
Fixed  
-14.25 to -15.75  
OUTPUT VOLTAGE SETTING[V] 4.9 to 5.3  
OVERCURRENT PROTECTION Works over 105% of rating and recovers automatically  
(
)
OVERVOLTAGE PROTECTION Works over 115% of rating by zener diode clamping +5V only  
PROTECTION  
CIRCUIT AND OPERATING INDICATION  
Not provided  
Not provided  
Not provided  
OTHERS  
REMOTE SENSING  
REMOTE ON/OFF  
INPUT-OUTPUT  
,
,
,
(
)
)
)
AC3 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature  
W
, , , (  
AC2 000V 1minute Cutoff current = 10mA DC500V 50M min At Room Temperature  
W
INPUT-FG  
OUTPUT-FG  
ISOLATION  
,
,
(
AC500V 1minute Cutoff current = 100mA DC500V 50M min At Room Temperature  
W
(
,
)
,
,
(
)
OUTPUT-OUTPUT V1-V2 V3 AC100V 1minute Cutoff current = 100mA DC100V 10M min At Room Temperature  
W
,
,
,
(
(
)
(
),  
,
(
,
)
OPERATING TEMP. HUMID.AND ALTITUDE -10 to +60  
20 - 90%RH Non condensing Refer to DERATING CURVE 3 000m 10 000feet  
C
,
),  
,
(
,
)
STORAGE TEMP. HUMID.AND ALTITUDE -20 to +75  
20 - 90%RH Non condensing 9 000m 30 000feet  
C
ENVIRONMENT  
2
,
(
),  
,
,
VIBRATION  
10 - 55Hz 19.6m/s 2G 3minutes period 60minutes each along X Y and Z axis  
IMPACT  
196.1m/s2 20G 11ms once each X Y and Z axis  
),  
(
,
,
SAFETY AND  
NOISE  
, , ,  
UL60950-1 EN60950-1 EN50178 CSA C22.2 No.60950-1 Complies with DEN-AN and IEC60950-1  
AGENCY APPROVALS  
CONDUCTED NOISE  
CASE SIZE/WEIGHT  
COOLING METHOD  
,
,
,
Complies with FCC-B CISPR22-B EN55022-B VCCI-B  
] (  
REGULATIONS  
[
)
W H  
X X  
(
)
50 26 127mm 1.97X1.02X5 inches  
D /150g max with chassis & cover : 300g max  
X
X
OTHERS  
Convection  
*1 Peak load for 10sec. or less is acceptable if the total wattage is less than the rated wattage(-1: 16W, -2: 17.5W).When the load of +5V is OA, other output can be drawn by 80% of rated current.  
*2 Measured by 20MHz oscilloscope or Ripple-Noise meter (equivalent to KEISOKU-GIKEN:RM101).  
*3 Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C with the input voltage held constant at the rated input/output.  
*4 Please contact us about safety approvals for the model with option.  
*
*
Avoid prolonged use under over-load.  
Derating is required when operated with chassis and cover.  
M arch 13, 2019  
LDC-2  

与LDC15F-2-S相关器件

型号 品牌 获取价格 描述 数据表
LDC15F-2-SC COSEL

获取价格

AC/DC PS (OPEN FRAME)
LDC15F-2-SG COSEL

获取价格

AC/DC PS (OPEN FRAME)
LDC15F-2-SN COSEL

获取价格

AC/DC PS (OPEN FRAME)
LDC15F-2-SNG COSEL

获取价格

AC/DC PS (OPEN FRAME)
LDC15F-2-SNY COSEL

获取价格

AC/DC PS (OPEN FRAME)
LDC15F-2-SY COSEL

获取价格

AC/DC PS (OPEN FRAME)
LDC15F-2-Y COSEL

获取价格

AC/DC PS (OPEN FRAME)
LDC15H100K0897 MURATA

获取价格

Analog Circuit
LDC15H100L1747 MURATA

获取价格

Directional Coupler, 1710MHz Min, 1785MHz Max, 1dB Insertion Loss-Max
LDC15H140J1747 MURATA

获取价格

Directional Coupler, 1710MHz Min, 1785MHz Max, 0.9dB Insertion Loss-Max