55W Constant Power MODE Linear LED Driver
LDC-55 series
SPECIFICATION
MODEL
LDC-55
OUTPUT CURRENT REGION 500 ~ 1600mA(500mA default)
RATED POWER Note.2 55W
CONSTANT CURRENT REGION Note.2 27 ~ 56V
FULL POWER CURRENT RANGE
OPEN CIRCUIT VOLTAGE(max.)
980 ~ 1600mA
60V
OUTPUT
LOW FREQUENCY
CURRENT RIPPLE
3.0% max. @rated current
CURRENT TOLERANCE
SET UP TIME Note.4
5.0%
500ms/230VAC
180 ~ 295VAC
VOLTAGE RANGE Note.3
FREQUENCY RANGE
POWER FACTOR (Typ.)
(Please refer to "STATIC CHARACTERISTIC" section)
47 ~ 63Hz
PF≧0.95/230VAC@load≧50%; PF≧0.9/277VAC@load≧75%
(Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
THD< 10%(@load≧50%/230VAC; @load≧75%/277VAC)
(Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
TOTAL HARMONIC DISTORTION
INPUT
EFFICIENCY (Typ.) Note.6 90%(230VAC@Full load)
AC CURRENT (Typ.)
0.35A / 230VAC
0.25A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 30A(twidth=300μs measured at 50% Ipeak)/230VAC; Per NEMA 410
MAX. No. of PSUs on 16A
CIRCUIT BREAKER
17 units (circuit breaker of type B) / 29 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
SHORT CIRCUIT
<0.75mA / 277VAC
Hiccup mode or constant current limiting ,recovers automatically after fault condition is removed
61 ~ 80V
OVER VOLTAGE
PROTECTION
FUNCTION
Shut down o/p voltage with auto-recovery or re-power on to recovery
OVER TEMPERATURE
DIMMING
Shut down o/p voltage, with auto-recovery
Please refer to“DIMMING OPERATION”section
By external NTC, please refer to“TEMPERATURE COMPENSATION OPERATION”section
Tcase=-25 ~ +80℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
Tcase=+80℃
TEMP. COMPENSATION
WORKING TEMP.
MAX. CASE TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
20 ~ 95% RH non-condensing
ENVIRONMENT
-40 ~ +80℃, 10 ~ 95% RH
0.03%/℃ (0 ~ 60℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL8750, CSA C22.2 No. 250.13-12; ENEC EN61347-1, EN61347-2-13, AS/NZS 61347.1:2016, AS/NZS IEC 61347.2.13:2013;
EN62384; GB19510.14,GB19510.1, EAC TP TC 004 approved
SAFETY STANDARDS Note.5
DALI STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION Note.5
EMC IMMUNITY
MTBF
Compliance to IEC62386-101.102.207 for DA-Type only
I/P-O/P:3.75KVAC I/P-FG:2.0KVAC O/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
SAFETY &
EMC
Compliance to
EN55015,EN61000-3-2 Class C (@load≧50%) ; EN61000-3-3;GB/T17743,GB17625.1,EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level(surge immunity:Line-Earth:2KV,Line-Line:1KV),EAC TP TC 020
226.1Khrs min. MIL-HDBK-217F (25℃)
320*30*21mm (L*W*H)
DIMENSION
OTHERS
NOTE
0.255Kg;48pcs/13.24Kg/0.92CUFT
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
2. Please refer to " OUTPUT CURRENT SETTING ".
3. De-rating may be needed under low input voltages. Please refer to STATIC CHARACTERISTIC sections for details.
4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
5. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
6. The DA type power supply is less efficient than the typical efficiency in specification by 2%.
7. This series meets the typical life expectancy of >50000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
File Name:LDC-55-SPEC 2018-08-03