POWER
LCM1000
Data Sheet
1000 Watt Bulk Front End
Total Power: 1000 W
# of Outputs: Single
Outputs:
12 to 48 V
Optional 5.0 V standby
SPECIAL FEATURES
1000 W output power
Low cost
2.5” x 5.2” x 10.0”
7.7 Watts per cubic inch
Industrial/Medical safety
-40 °C to 70 °C with derating
Electrical Specifications
Input
Optional 5 V @ 2 A
housekeeping
Input range
90 - 264 Vac (Operating)
115/230 Vac (Nominal)
TERMINAL BLOCK
High efficiency: 90% typical
Variable speed “Smart Fans”
DSP controlled
Frequency
47 - 440 Hz, Nominal 50/60
Input fusing
Internal 30 A fuses, both lines fused
≤ 25 A peak, either hot or cold start
0.99 typical, meets EN61000-3-2
Meets IEC 1000-3-2 requirements
12 A RMS max input current, at 100 Vac
20 ms minimum for Main O/P, at full rated load
> 90% typical at full load / 230 Vac nominal
< 0.4 mA at 264 Vac
Full rating with reverse airflow
Conformal coat option
Inrush current
Power factor
Harmonics
10% adꢀustment range
Margin programming
OR-ing FET
Input current
Hold up time
Efficiency
Low acoustic noise
Leakage current
ON/OFF power switch
COMPLIANCE
EMI Class A; Class B with internal
modification option
N/A
Power line transient
Isolation
MOV directly after the fuse
PRI-Chassis 2500 Vdc Basic
PRI-SEC 4000 VAC Reinforced 2xMOPP
SEC-Chassis 500 Vdc
EN61000 Immunity
RoHS 2
SAFETY
ULcUL Recognized ITE (UL60950-1)
LCM1000L-T Efꢀciency Without the 5 Vsb
92.00
90.00
88.00
86.00
84.00
82.00
80.00
78.00
76.00
ULcUL Recognized Medical
(ANSI/AAMI ES60601-1)
TUV-SuD ITE + Medical
(EN60950-1 and EN60601-1)
100 Vac
230 Vac
CE LVD (EN60950-1 + ROHS)
BSMI
CB Report
- through Demko for IEC60950-1
- through TUV-SuD for IEC60601-1
25
50
75
100
CCC Approval
Loading %