Absolute Maximum Ratings @ 25ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
250
Units
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
50
V
mA
A
1
Input Power Dissipation 1
Total Power Dissipation 2
Isolation voltage, Input to Output
Operational Temperature, Ambient
Storage Temperature
150
mW
mW
Vrms
°C
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
800
3750
-40 to +85
-40 to +125
°C
1
1
Derate linearly 1.33 mW / ºC
Derate output power linearly 6.67 mW / ºC
Electrical Characteristics @ 25ºC
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Blocking Voltage
IL=1A
VDRM
250
-
-
VP
Load Current
Continuous, AC/DC Configuration
Continuous, DC Configuration
Peak
-
-
-
-
-
-
170
300
400
mArms / mADC
mADC
-
IL
IL
t=10ms
mAP
On-Resistance 1
AC/DC Configuration
DC Configuration
IL=170mA
IL=300mA
-
-
-
11
5
20
6
RON
Off-State Leakage Current
Switching Speeds
IF=5mA, VL=250VP
ILEAK
-
1
A
Turn-On
ton
toff
-
-
-
0.65
1.30
50
5
5
-
ms
ms
pF
IF=5mA, VL=10V
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
VL=50V, f=1MHz, IF=5mA
COUT
IL=170mA
-
IF
IF
-
-
5
-
mA
mA
V
0.4
0.9
-
-
1.36
-
IF=5mA
VR=5V
VF
IR
1.5
10
Reverse Input Current
Common Characteristics
Input to Output Capacitance
A
VIO=0V, f=1MHz
CIO
-
3
-
pF
1
Measurement taken within 1 second of on-time.
2
R11