LBA127
INTEGRATED
CIRCUITS
DIVISION
Absolute Maximum Ratings @ 25°C
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings Units
250
VP
Reverse Input Voltage
Input Control Current
Peak (10ms)
5
50
V
mA
A
1
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
Input Power Dissipation 1
Total Power Dissipation 2
Isolation Voltage, Input to Output
Operational Temperature, Ambient
Storage Temperature
150
mW
mW
Vrms
°C
800
3750
-±0 to +85
-±0 to +125
°C
1
Derate linearly 1.33 mW / °C
Derate output power linearly 6.67 mW / °C
2
Electrical Characteristics @ 25°C
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Blocking Voltage
IL=1A
VDRM
250
-
-
VP
Load Current, AC/DC
Continuous 1
-
IL
-
-
-
-
-
-
200
±±00
10
mArms / mADC
Peak
On-Resistance 2
t = 10ms
IL=200mA
VL=250VP
ILPK
RON
ILEAK
mAP
6.8
-
Off-State Leakage Current
Switching Speeds
1
A
Turn-On
ton
toff
-
-
-
-
-
5
5
-
IF=5mA, VL=10V
VL=50V, f=1MHz
ms
pF
Turn-Off
Output Capacitance
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
Reverse Input Current
Common Characteristics
COUT
110
IL=200mA
-
IF
IF
-
-
0.7
1.36
-
5
-
mA
mA
V
0.±
0.9
-
IF=5mA
VR=5V
VF
IR
1.5
10
A
Input to Output Capacitance
1
VIO=0V, f=1MHz
CIO
-
3
-
pF
If both poles operate simultaneously, then the load current must be derated so as not to exceed the package power dissipation value.
Measurement taken within 1 second of on-time.
2
2
R15
www.ixysic.com