LAA100
INTEGRATED
CIRCUITS
DIVISION
Absolute Maximum Ratings @25ºC
Absolute Maximum Ratings are stress ratings. Stresses in
excess of these ratings can cause permanent damage to
the device. Functional operation of the device at conditions
beyond those indicated in the operational sections of this
data sheet is not implied.
Parameter
Blocking Voltage
Ratings
350
Units
VP
Reverse Input Voltage
5
50
V
Input Control Current
Peak (10ms)
mA
A
1
Typical values are characteristic of the device at +25°C,
and are the result of engineering evaluations. They are
provided for information purposes only, and are not part of
the manufacturing testing requirements.
Input Power Dissipation 1
Total Power Dissipation 2
150
mW
mW
Vrms
ºC
800
Isolation Voltage, Input to Output
Operational Temperature, Ambient
Storage Temperature
3750
-40 to +85
-40 to +125
ºC
1
2
Derate linearly 1.33 mW / ºC
Derate output power linearly 6.67 mW / ºC
Electrical Characteristics @ 25ºC
Parameter
Conditions
Symbol
Min
Typ
Max
Units
Output Characteristics
Blocking Voltage
Load Current
IL=1A
VDRM
350
-
-
V
Continuous 1
-
IL
-
-
-
-
-
-
-
-
120
350
25
mArms / mADC
Peak
10ms
ILPK
RON
ILEAK
mAP
On-Resistance 2
Off-State Leakage Current
Switching Speeds
IL=120mA
VL=350V
1
µA
Turn-On
ton
toff
-
-
-
-
-
5
5
-
ms
ms
pF
IF = 5mA, VL = 10V
Turn-Off
Output Capacitance
IF=0mA, VL = 50V, f=1MHz
COUT
35
Input Characteristics
Input Control Current to Activate
Input Control Current to Deactivate
Input Voltage Drop
IL = 120mA
-
IF
IF
-
-
0.7
1.36
-
5
-
mA
mA
V
0.4
0.9
-
IF = 5mA
VR = 5V
VF
IR
1.5
10
Reverse Input Current
Common Characteristics
Capacitance Input to Output
µA
VIO=0V, f=1MHz
CIO
-
3
-
pF
1 If both poles operate, the load current must be derated so that the package power dissipation value is not exceeded.
2 Measurement taken within 1 second of on-time.
2
R04