KBU1001G THRU KBU1007G
Single Phase 10 AMPS. Glass Passivated Bridge Rectifiers
Voltage Range
50 to 1000 Volts
Current
10.0 Amperes
KBU
Features
.185(4.7)
.165(4.2)
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
UL Recognized File # E-96005
Glass passivated junction
.935(23.7)
.895(22.7)
.280(7.1)
.260(6.6)
.160(4.1)
.140(3.6)
Ideal for printed circuit board
Reliable low cost construction
Plastic material has Underwriters
Laboratory Flammability Classification
94V-0
.085(2.2)
.065(1.7)
450
.70(17.8)
.66(16.8)
.455(11.3)
.405(10.3)
.760(19.3)
MAX
ꢀ
ꢀ
Surge overload rating to 200 amperes
peak
.165(4.2)
.150(3.8)
1.0(25.4)
MIN
High temperature soldering guaranteed:
260oC / 10 seconds / .375”, (9.5mm) lead
lengths at 5 lbs., (2.3kg) tension
Weight: 0. 3 ounce, 8.0 grams
Mounting torque: 5 in. lb. Max.
.260(6.8)
.180(4.5)
.220(5.6)
.180(4.6)
ꢀ
ꢀ
.052(1.3)
.048(1.2)
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%
Symbol KBU KBU KBU KBU KBU KBU KBU
Type Number
Units
1001G 1002G 1003G 1004G 1005G 1006G 1007G
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
50 100 200 400 600 800 1000
V
V
V
VRRM
VRMS
VDC
35
70 140 280 420 560 700
Maximum DC Blocking Voltage
50 100 200 400 600 800 1000
Maximum Average Forward Rectified Current
@TA =45℃
10.0
A
A
V
I(AV)
Peak Forward Surge Current, 8.3 ms Single
Half Sine-wave Superimposed on Rated
Load (JEDEC method )
Maximum Instantaneous Forward Voltage
@ 10.0A
200
1.1
IFSM
VF
IR
Maximum DC Reverse Current @ TA=25℃
at Rated DC Blocking Voltage @ TA=125℃
5.0
500
2.2
uA
uA
℃/W
℃
Typical Thermal Resistance (Note)
Operating Temperature Range
Storage Temperature Range
RθJC
TJ
-55 to +150
-55 to +150
℃
TSTG
Note: Thermal Resistance from Junction to Case with Device Mounted on 4” x 6” x 0.25”Al-Plate
Heatsink.
- 760 -