DG186/187/188
Vishay Siliconix
a
SPECIFICATIONS For DG186
Test Conditions
Unless Specified
Limits
V+ = 15 V, V– = –15 V, V = 5 V
L
Tempb
Mind
Typc
Maxd
Unit
f
Parameter
Analog Switch
Symbol
V
R
= 0 V, V = 0.8 or 2 V
IN
e
Analog Signal Range
V
Full
–7.5
15
V
ANALOG
Drain-Source
On-Resistance
Room
Full
7.5
10
20
r
I = –10 mA, V = –7.5 V
S D
W
DS(on)
V
= "10 V, V = #10 V
Room
Hot
0.05
0.05
0.04
0.03
–0.1
300
10
1000
S
D
V+ = 10 V, V– = –20 V
Source Off
Leakage Current
I
S(off)
Room
Hot
10
1000
V
S
= "7.5 V, V = #7.5 V
D
V
S
= "10 V, V = #10 V
Room
Hot
10
1000
D
nA
V+ = 10 V, V– = –20 V
Drain Off
Leakage Current
I
I
D(off)
Room
Hot
10
1000
V
S
= "7.5 V, V = #7.5 V
D
Channel On
Leakage Current
Room
Hot
–2
–200
V
D
= V = "7.5 V
D(on)
S
Saturation Drain Current
I
2 ms Pulse Duration
Room
mA
DSS
Digital Input
Input Current with
Input Voltage High
Room
Hot
<0.01
–30
10
20
I
V
V
= 5 V
= 0 V
INH
IN
mA
Input Current with
Input Voltage Low
I
Full
–250
INL
IN
Dynamic Characteristics
Turn-On Time
t
Room
Room
Room
Room
Room
Room
240
140
21
400
200
on
See Switching Time Test Circuit
ns
Turn-Off Time
t
off
Source-Off Capacitance
Drain-Off Capacitance
Channel-On Capacitance
Off Isolation
C
C
C
V
V
= –5 V, I = 0
D
S(off)
D(off)
D(on)
S
f = 1 MHz
= –5 V, I = 0
17
pF
dB
D
S
V
D
= V = 0 V
17
S
OIRR
f = 1 MHz, R = 75 W
>55
L
Power Supplies
Positive Supply Current
Negative Supply Current
Logic Supply Current
I+
I–
Room
Room
Room
Room
0.8
3.2
–3
–2
V
IN
= 0 V, or 5 V
mA
I
L
Reference Supply Current
I
R
Notes:
a. Refer to PROCESS OPTION FLOWCHART.
b. Room = 25_C, Full = as determined by the operating temperature suffix.
c. Typical values are for DESIGN AID ONLY, not guaranteed nor subject to production testing.
d. The algebraic convention whereby the most negative value is a minimum and the most positive a maximum, is used in this data sheet.
e. Guaranteed by design, not subject to production test.
f.
V
IN
= input voltage to perform proper function.
Document Number: 70033
S-52895—Rev. E, 16-Jun-97
www.vishay.com S FaxBack 408-970-5600
4-3