MODEL: JAPD2  
RNG4 10 Hz: 0 – 20 Hz  
RNG5 1 Hz: 0 – 2 Hz  
RELATED PRODUCTS  
• Programming Unit (model: PU-2x)  
RNG6 100 mHz: 0 – 200 mHz  
Min. span: 10 % of available frequency range  
Duty ratio: 50 %  
• PC configurator software (model: JXCON)  
Downloadable at M-System’s web site.  
A dedicated cable is required to connect the module to the  
PC. Please refer to the internet software download site or  
the users manual for the PC configurator for applicable  
cable types.  
Open Collector: 50 V DC @50 mA (resistive load)  
Saturation voltage: 0.6 V DC  
Voltage Pulse  
H level: Rating 5, 12 or 24 V ±10 %  
L level: ≤ 0.5 V  
GENERAL SPECIFICATIONS  
Construction: Plug-in  
Load resistance: ≥ 1 kΩ (5 V), ≥ 2.4 kΩ (12 V), ≥ 4.8 kΩ (24  
V)  
Connection: M3.5 screw terminals  
Screw terminal: Chromated steel (standard) or stainless  
steel  
Noncontact AC/DC Switch: 120 V AC or 120 V DC @200  
mA (resistive load)  
ON resistance: 3 Ω max.  
Housing material: Flame-resistant resin (black)  
Isolation: Input to alarm output to output to power  
Zero adjustment: -5 to +5 % (front)  
Span adjustment: 95 to 105 % (front)  
Alarm output: Turns on when the input goes above (high) or  
below (low) setpoint  
Rise time: 5 msec.  
Sink time: 3 msec.  
RS-422 Line Driver Pulse  
Transmitter: Conforms to RS-422  
Relay Contact:  
100 V AC @ 1 A (cos ø = 1)  
Alarm setpoint: -5 – +105 %  
120 V AC @ 1 A (cos ø = 1)  
Alarm deadband (hysteresis): 0 – 20 %  
Output monitor LED: Red LED turns on when the output is  
ON or high.  
240 V AC @ 0.5 A (cos ø = 1)  
30 V DC @ 1 A (resistive load)  
Maximum switching voltage: 380 V AC or 125 V DC  
Maximum switching power: 120 VA or 30 W  
Minimum load: 5 V DC @ 10 mA  
Power ON delay time: 2.0 to 1000.0 sec.  
Software programming: Programming Unit (model: PU-2x);  
(Refer to the users manual of JXCON for the adjustments  
configurable with JXCON)  
Mechanical life: 5 x 10 cycles (300 cycle/minute)  
7
• Output frequency (zero and span)  
• Alarm  
INSTALLATION  
Power input  
• Power ON delay time  
AC: Operational voltage range 85 – 264 V, 47 - 66 Hz;  
Approx. 3.2 VA at 100 V  
• Others  
Approx. 5.1 VA at 200 V  
INPUT SPECIFICATIONS  
DC Current:  
Approx. 6.9 VA at 264 V  
DC: Operational voltage range: rating ±10 %, or 85 – 150 V  
for 110 V rating (ripple 10 % p-p max.)  
Approx. 2.5 W (100 mA at 24 V)  
Shunt resistor attached to the input terminals (0.5 W)  
Specify input resistance value for code Z.  
DC Voltage: -300 – +300 V DC  
Minimum span: 10 mV  
Operating temperature: -5 to +55°C (23 to 131°F)  
Operating humidity: 30 to 90 %RH (non-condensing)  
Mounting: Surface or DIN rail  
Offset: Max. 1.5 times span  
Input resistance  
Weight: 280 g (0.62 lb)  
Span 10 – 100 mV : ≥ 10 kΩ  
Span 0.1 – 1 V : ≥ 100 kΩ  
Span ≥ 1 V : ≥ 1 MΩ  
OUTPUT SPECIFICATIONS  
Frequency range: 100 mHz to 10 kHz (RNG1 to RNG6)  
[ Range name : Available frequency ]  
RNG1 10 kHz: 0 – 20 kHz  
RNG2 1 kHz: 0 – 2 kHz  
RNG3 100 Hz: 0 – 200 Hz  
JAPD2 SPECIFICATIONS  
ES-1571 Rev.6 Page 2/4  
http://www.m-system.co.jp/  

与JAPD2-HP-R相关器件

型号 品牌 描述 获取价格 数据表
JAPD2-HP-R/Q MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

JAPD2-HP-S MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

JAPD2-HP-S/Q MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

JAPD2-H-R MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

JAPD2-H-R/Q MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格

JAPD2-HR-M2 MSYSTEM Plug-in Signal Conditioners M-UNIT

获取价格