J152
General Data*
Electrical Life @ rated load
Mechanical Life
500K cycles (2 pole), 200K cycles (3 pole), 100K (4 pole) average
20M cycles (2 pole), 10M cycles (3 & 4 pole), average
100M Ω min. @ 500VDC initial
Insulation Resistance
Dielectric Strength, Coil to Contact
Contact to Contact
1500V rms min. @ sea level initial
1500V rms min. @ sea level initial
2
Shock Resistance
100m/s for 11 ms
Vibration Resistance
Terminal (Copper Alloy) Strength
Operating Temperature
Storage Temperature
Solderability
1.27mm double amplitude 10~40Hz
10N
o
o
-40 C to +85 C
o
o
-40 C to +155 C
o
260 C for 5 s
Weight
32g
*
Values can change due to the switching frequency, desired reliability levels, environmental conditions and in-rush load levels. It is recommended to test actual load conditions for the
application. It is the user’s responsibility to determine the performance suitability for their specific application. The use of any coil voltage less than the rated coil voltage may compromise
the operation of the relay.
Ordering Information
1. Series
J152
J152
3C
T
12VDC
2. Contact Arrangement
2A, 2B, 2C
3A, 3B, 3C
4A, 4B, 4C
3. Termination
T = Solder lugs / Plug-in
F = Solder lugs / Plug-in with Flange
P = PCB Pins
4. Coil Voltage
12VAC
24VAC
110VAC
120VAC
220VAC
12VDC
24VDC
110VDC
5. Optional LED
Blank = No indicator LED
D = With indicator LED
6. Gold Option
Blank = Standard contacts
G = Gold over standard contacts
7. Push to Test Option
Blank = Without push to test button
T = With push to test button
page 2
www.citrelay.com phone - 763.535.2339 fax - 763.535.2194
Dimensions shown in mm. Dimensions are shown for reference purposes only.
Specifications and availability subject to change without notice.