DC-DC Converter
ITW Series
EMC: Emissions
Phenomenon
Conducted
Radiated
Standard
EN55022
EN55022
Test Level
Class A
Notes & Conditions
See Application Note
See Application Note
Class A
EMC: Immunity
Phenomenon
ESD Immunity
Radiated Immunity
EFT/Burst
Standard
Test Level
Criteria
Notes & Conditions
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
3
20 Vrms
3
A
A
A
A
A
A
External input capacitor required 330 µF/100 V
External input capacitor required 330 µF/100 V
Surges
Installation class 2
3 V rms
Conducted Immunity
Magnetic Fields
1 A/m
Mechanical Details
0.30
(7.62)
0.67 (17.0)
Printed Face
0.41
(10.50)
0.43
(11.0)
d/c
6
0.50
(0.02)
1
2
4
5
0.12
(3.00)
0.08
(2.15)
0.20
(5.08)
0.08
(2.15)
0.09
(2.38)
0.10
(2.54)
0.01
(0.25)
0.50
(12.7)
0.02
(0.50)
0.02
(0.50)
0.30
(7.62)
1
2
4
5
6
0.01
(0.25)
0.10
(2.50)
Pin Connections
Single
-Vin
+Vin
0.02
(0.50)
Pin
1
2
Dual
-Vin
+Vin
4
5
6
+Vout
N.P.
-Vout
+Vout
Common
-Vout
Notes
1. All dimensions are in inches (mm)
2. Weight: 0.0067 lbs (3.0 g) approx.
3. Pin diameter: 0.02 0.002 (0.5 0.05)
4. Pin pitch tolerance: 0.014 ( 0.35)
5. Case tolerance: 0.02 ( 0.5)
www.xppower.com