ISD14B00
7.2.
AC PARAMETERS
CHARACTERISTIC [1]
Sampling Frequency
Record Duration
SYMBOL MIN[2]
TYP
MAX[2] UNITS
CONDITIONS
[3]
[3]
[3]
Fs
4
10.6
10.6
225k/Fs
30
225k/Fs
30
12
32
32
kHz
sec
sec
TREC
TPLAY
TDeb
TASet
TAHold
TFSet
TSettle1
TSettle2
Playback Duration
Debounce Time
Address Setup Time
Address Hold Time
FMC Setup Time
Record Settle Time
Play Settle Time
Delay from Record to Play TSettle3
[3] [4]
msec
nsec
msec
nsec
msec
msec
msec
nsec
msec
[3] [4]
[3] [4]
[3] [4]
[3] [4]
32k/Fs
256k/Fs
128k/Fs
Record Stop Time
LED Pulse Low Time
TStop1
TEOM
30
[3] [4]
256k/Fs
Notes:
[1]
Conditions are VCC = 5.5V, TA = 25°C and sampling frequency (FS) at 8kHz, unless specified.
[2]
[3]
[4]
Not all specifications are 100 percent tested. All Min/Max limits are guaranteed by Nuvoton via design,
electrical testing and/or characterization.
When different FS is applied, the value will change accordingly. Also, stability of internal oscillator may
vary as much as +10% over the operating temperature and voltage ranges.
k = 1000.
Publication Release Date: Jan 19, 2009
- 21 -
Revision 0.30