IP137A SERIES LM137A SERIES
IP137A SERIES LM137A SERIES
IP337A SERIES
IP337A SERIES
IP137A , IP137AHV
IP137 , IP137HV
LM137A , LM137AHV
LM137 , LM137HV
Parameter
Test Conditions
OUT = 10mA
IOUT =10mA to IMAX T = -55 to 150°C
Min.
Typ.
Max.
Min.
Typ.
Max. Units
I
-1.238
-1.25
-1.262
-1.225
-1.25
-1.275
V
VREF
Reference Voltage
J
VIN – VOUT = 3V to VMAX
P ≤ PMAX -1.220
-1.25
0.005
0.010
5
-1.280
0.010
0.030
25
-1.200 -1.250 -1.300
V
VIN – VOUT = 3V to VMAX
0.010
0.020
15
0.020
0.050
25
∆VOUT
∆IOUT
1
%/V
Line Regulation
TJ = -55 to 150°C
IOUT = 10mA to IMAX
V
OUT ≤ 5V
OUT ≥ 5V
OUT ≤ 5V
OUT ≥ 5V
mV
%
V
V
V
0.1
0.5
0.3
0.5
∆VOUT
∆IOUT
1
Load Regulation
IOUT = 10mA to IMAX
TJ = -55 to 150°C
tp = 10ms
10
50
20
50
mV
%
0.2
1
0.3
1
TA = 25°C
LCC4 Package
CADJ = 0
0.002
0.020
0.040
0.002
0.02
0.040
Thermal Regulation
%/W
dB
60
70
66
80
60
77
VOUT = -10V
C
ADJ = 10µF
Ripple Rejection
f = 120Hz
66
dB
TJ = -55 to 150°C
TJ = -55 to 150°C
65
0.2
1.0
100
2
65
0.5
2
100
5
µA
IADJ
Adjust Pin Current
IOUT = 10mA to IMAX
TJ = -55
VIN – VOUT = 3V to 40V
VIN – VOUT = 3V to 50V
(HV SERIES)
5
5
∆IADJ Adjust Pin Current
µA
mA
A
to 150°C
Change
2.0
6
3
6
VIN – VOUT ≤ 40V
2.5
1.2
2.2
0.4
5
3
2.5
1.2
2.2
0.4
5
3
IMIN
Minimum Load
Current
TJ = -55 to 150°C
TJ = -55 to 150°C
TJ = -55 to 150°C
VIN – VOUT ≤ 10V
VIN – VOUT ≤ 15V
VIN – VOUT = 40V
1.5
3.2
1
1.5
3.2
0.24
0.24
ICL
Current Limit
V
IN – VOUT = 50V
0.2
0.4
0.6
0.8
1.5
1
0.2
0.4
0.6
0.8
1
(HV SERIES)
∆VOUT Temperature
∆TEMP Stability
∆VOUT
%
%
%
TA = +125°C
t = 1000 Hrs
f = 10 Hz to 10 kHz
TA = 25°C
0.3
0.3
Long Term Stability
∆TIME
en
RMS Output Noise
(% of VOUT
0.003
0.003
)
K Package
2.3
5
3
7
2.3
5
3
7
RθJC
Thermal Resistance
Junction to Case
R Package
°C/W
G Package
3
5
3
5
LCC4 Package
13
13
1) Regulation is measured at constant junction temperature, using pulse testing at a low duty cycle. Changes in output voltage due to heating effects are covered under
1
thermal regulation specifications. Load regulation is measured at a point / ” from the bottom of the package for the TO–3 and TO–66 packages, at the junction of the
8
1
wide and narrow portion of the output lead for the SMD packages, and / ” below the base of the package on the output pin of the TO–257 package.
8
2) Test Conditions unless otherwise stated: V – V
IN
= 5V , I
OUT
= 0.5A , P
MAX
= 20W , I
MAX
= 1.5A, V = 40V for standard series , 50V for HV series.
MAX
OUT
Semelab Plc reserves the right to change test conditions, parameter limits and package dimensions without notice. Information furnished by Semelab is believed
to be both accurate and reliable at the time of going to press. However Semelab assumes no responsibility for any errors or omissions discovered in its use.
Semelab encourages customers to verify that datasheets are current before placing orders.
Semelab plc. Telephone +44(0)1455 556565. Fax +44(0)1455 552612.
Document Number 2831
Issue 3
E-mail: sales@semelab.co.uk
Website: http://www.semelab.co.uk