IMP2119
Recommended Operating Conditions2
Parameter
Symbol
Min
3.0
3.5
0
Typ
Max
5.25
5.25
5.0
Units
TermPwr Voltage
LVD
SE
VTERM
V
Signal Line Voltage
V
V
Disconnect Input Voltage
0
VTERM
70
Operating Virtual Junction Temperature Range
Note: 2. Range over which the device is functional.
0
°C
5241/42_t03.eps
Electrical Characteristics
Unless otherwise specified, these specifications apply over the operating ambient temperature range of 0°C ≤ TA ≤ 70°C. TermPwr = 4.75V.
ISO IMP2119 LOW. Low duty cycle pulse testing techniques are used which maintain
junction and case temperatures equal to the ambient temperature.
:
=
Parameter
LVD Terminator Section
TermPwr Supply Current
Symbol Condition
Min Typ Max Units
LVD ICC All terminator lines = Open
25
1
30
35
mA
ISO> 2.0 V
µA
Common Mode Voltage
Offset Voltage
Differential Terminator Impedance
Common Mode Impedance
Output Capacitance
VCM
VFSB
ZD
1.125 1.25 1.375
V
mV
Ω
Ω
pF
Open circuit between – and + (see Note 3)
VOUT differential = –1V to 1V
0V to 2.5V
100
100
100
112
105
200
2.5
125
110
300
ZCM
CO
ISO > 2.0 V
Output Leakage
ILEAK
ISO > 2.0V
2
µA
VLINE = 0V to 4V, TA = 25°C
ISO > 2.0 V
1
TPWR = 0V, VLINE = 2.7V
Mode Change Delay
tDF
DIFFSENSE = 1.4V to 0V
115
1.3
ms
DIFFSENSE Section
DIFFSENSE Output Voltage
DIFFSENSE Output Source Current
DIFFSENSE Sink Current
DIFFSENSE Output Leakage
VDIFF
IDIFF
1.2
5.0
1.4
15.0
200
10
V
VDIFF = 0V
mA
µA
µA
ISINK (DIFF) VDIFF = 2.75V
ILEAK (DIFF) ISO > 2.0V
TA = 25°C
Single-Ended Terminator Section
TermPwr Supply Current
SE ICC
All terminator lines = Open, MASTER/SLAVE = 0V
All terminator lines = 0.2V, MASTER/SLAVE = 0V
DISCONNECT > 2.0V
7
10
226
35
mA
214
15
µA
V
mA
mA
pF
µA
Terminator Output High Voltage
Output Current
Sink Current
VO
IO
ISINK
CO
2.6
21
45
2.85
23
65
VOUT = 0.2V
VOUT = 4V, all lines
ISO > 2.0V
24
2
Output Capacitance
Leakage Current
2.5
ILEAK
ISO > 2.0V
V
OUT = 0V to 4V, TA = 25°C
ISO > 2.0V
I
TPWR= 0V, LINE = 2.7V, TA = 25°C
Ground Driver Impedance
Thermal Shutdown
ZG
I = 1mA
100
Ω
150
°C
Note: 3. Open circuit fallsafe voltage.
4
408-432-9100/ www.impweb.com
© 2002 IMP, Inc.