IGD-8-426-E1F12-BH-FA
Characteristics
Symbol Conditions
Electrical Data
min.
typ.
max.
Unit
no overload
Irms
1490
1600
A
A
Tamb=40°C,
3kHz, 650Vdc,
400Vac, cos=0,85
110% overload,
60s every 10min
150% overload,
60s every 10min
1460
1140
1700
A
VCES
1200
V
fsw
max. switching frequency
15.6
kHz
IGBT Module Stack
DC voltage applied to the capacitor
bank
VDC
750
460
V
V
network voltage (line side), -20% /
+15%
VAC
Three-phase inverter
Visol
Ptot
Tj
50Hz / 1min
2500
11720
125
V
SEMIKUBE - Size 3H
IGD-8-426-E1F12-BH-FA
Preliminary Data
Tamb=40°C
W
°C
Tvj for continous operation
-40
Capacitor Data
Features
CDC
C
SKC4M7-40A1
42.3
mF
Electrolyt
• Highly compact
• Integrated current, voltage and
temperature sensors
expected lifetime calculated, forced air
cooling
LTE
60
30
kHrs
kHrs
expected lifetime calculated, w/o
forced air cooling
• Easy maintenance
• Easy mounting and dismounting
• Very high Life-Time Expectancy
• Very low inductive DC bus
Controller Interface Data
VS
supply voltage primary side
21.6
24
26.4
1200
V
supply current primary side (+ external
current sensors)
Typical Applications
ISO
270
mA
VIT+
VIT-
Input threshold voltage (HIGH)
Input threshold voltage (LOW)
Input resistance
0,7*Vs
V
V
• Industrial
• AC motor control
• UPS
• Solar inverter
• Oil and gas pumps
0.3*Vs
RIN
10
kΩ
ITRIPSC
Ttp
Over current trip level
3600
100
APEAK
°C
Over temperature protection level
No. 08800900
Mechanical Data
dv/dtAIR
w
required airflow per fan
620
m3/h
kg
Footnotes
Electrical parameters to be derated for Tamb
> 40°C
approx. total weight
110
752
Size
Width x Depth x Height (with fan)
w/o need of reforming the caps
1122
-20
544
40
mm
°C
Tstg
Tamb
-20
55
°C
Ths
°C
Alltitude
Protection
installation height w/o derating
1000
m
IP00
2
Pollution EN 50178
Fan Data
included in the stack ( NO )
Fan
Type
VFan
fFAN
(SKF 16 O-230-01)
Fan voltage
230
50
V
Hz
A
Fan frequency
Fan current
IFAN
1.3
300
PFAN
Fan power
W
B6CI
© by SEMIKRON
Rev. 0 – 03.08.2009
1