F-203 SUPPLEMENT
IDSS–05–S–4
EDMS–05–S–4
IDMS, IDMD, IDSS, IDSD
IDC CABLE STRIPSEDMS & EDMD SERIES
ASSEMBLED
OPTION
LENGTH
POLARIZING KEY
(0,64) .025
Assembled Length in
SQ
Optional polarizing key for
use with IDSS & IDSD
Series. Also polarizes
SSW, SSQ, ESW & ESQ
Series. Black High
INCHES ( 1/8" )
(2 inches minimum)
(5,84)
.230
Temperature Thermoplastic
Order: Part Number PK-01
Tin Plating
(Both ends)
=
=
=
–T
–C
–A
–ST “X”
–S “XX”
–R
= Stripped & Tinned
= Daisy Chain Single
= Reversed
Tin IDM/
10µ" (0,25µm) Gold IDS
Specify Suffix from table. All
2"
min.
“XX” 1⁄8"
1
dimensions are /16 ". Not available
Single Row
Connectors
(IDSS)
in 28 positions and higher.
10µ" (0,25µm) Gold IDM/
Tin IDS
Standard plating is selective
gold over BeCu contact for IDS;
Selective gold over phosphor
bronze for IDM & EDM.
Outer Most
4" minimum
When mating double row
connector with two single row
connectors, the outer most
single will be connected to
Conductor #1 and the inside
single to Conductor #2.
1
8
1/8" (3,18)
–ST8
–ST4
–ST2
–ST3
1/4" (6,35)
–M
–P “XX”
= Middle Reversed
1/2" (12,70)
=Polarized
3/8" (9,53)
4
7
72
71
04 02
–D “XX”
–B “XX”
= Daisy Chain, Double
= Breakout
2"
min.
03 01
1
“XX”
⁄8"
Specify “XX” as number of
conducts to be broken out.
Specify “XX” as position. For
Double the same position will
be polarized on both ends. (Not
available on IDM or EDM,
unless Transfer, then only the
socket is polarized)
Double Row
Connectors
(IDSD or
Requires –SXX, –WXX or –DXX
IDMD)
8
Outer Most
–O
2
“XX”
= Outside Reversed
4" minimum
7
–G
5"max.
2"min.
= Gray Cable
–W “XX”
= Wiring Reversed
Daisy Chain, Single
Breakout starts with Number 1
lead indicated by brown wire or
red stripe. Shown on top side.
Specify –G for Gray cable.
Gray cable has one red edge.
IDSS uses .100" centerline
cable. IDSD and IDMD uses
.050" centerline cable. Cable is
28 AWG 7/36 copper wire.
Standard cable is same as
above except color coded.
5
Same as –S “XX” except outer
strip connected to Conductor
#2 and inside strip connected
to Conductor #1.
–RW
= Reversed Wiring
Requires –SXX, –WXX or –DXX
#1 wire opposite position #1.
3
6
7
8
Due to technical progress, all designs, specifications and components are subject to change without notice.
WWW.SAMTEC.COM
SAMTEC USA • Tel: 1-800-SAMTEC-9 or 812-944-6733 • Fax: 812-948-5047 SAMTEC UK • Tel: 01236 739292 • Fax: 01236 727113 SAMTEC GERMANY • Tel: +49 (0) 89 / 89460-0 • Fax: +49 (0) 89 / 89460-299
SAMTEC FRANCE • Tel: 01 60 95 06 60 • Fax: 01 60 95 06 61 SAMTEC ITALY • Tel: 39 039 6890337 • Fax: 39 039 6890315
SAMTEC ASIA PACIFIC • Tel: 65 6745-5955 • Fax: 65 6841-1502 SAMTEC CHINA • Tel: 86-21-5385-4089 • Fax: 86-21-5385-4047 SAMTEC JAPAN • Tel: 81-424-42-8318 • Fax: 81-424-42-8319
SAMTEC TAIWAN • Tel: 886-02-2364-6077 • Fax: 886-02-2367-9531 SAMTEC HONG KONG • Tel: 852-26904858 • Fax: 852-26904842 SAMTEC ANZ • Tel: 613 9512 7747 • Fax: 613 9512 7745