描述
Current Transducers HY 5 to 25-P/SP1

HY20-P/SP1 数据手册

 浏览型号HY20-P/SP1的Datasheet PDF文件第2页 
IPN = 5 .. 25 A  
Current Transducers HY 5 to 25-P/SP1  
For the electronic measurement of currents : DC, AC, pulsed...,  
with a galvanic isolation between the primary circuit (high power)  
and the secondary circuit (electronic circuit) with unipolar power  
supply.  
Electrical data  
Primary nominal  
r.m.s. current  
Primary current  
measuring range  
IP(A)  
Primary  
conductor  
(mm)  
Type  
IPN (A)  
Features  
5
± 15  
± 30  
± 37.5  
± 45  
± 60  
± 75  
0.7  
1.1  
1.4  
1.4  
HY 05-P/SP1  
HY 10-P/SP1  
HY 12-P/SP1  
HY 15-P/SP1  
HY 20-P/SP1  
HY 25-P/SP1  
Hall effect measuring principle  
Galvanic isolation between primary  
and secondary circuit  
10  
12.5  
15  
Isolation voltage 2500 V~  
20  
2 x  
1.2 1)  
2 x 1.4 1)  
Compact design for PCB mounting  
Low power consumption  
Extended measuring range (3 x IPN)  
Insulated plastic case recognized  
according to UL 94-V0.  
25  
VC  
IC  
Î P  
Supply voltage (± 5 %)  
Current consumption  
Overload capability (1 ms)  
single + 5  
V DC  
mA  
10  
50 x IPN  
Vd  
Vb  
R IS  
R.m.s. voltage for AC isolation test, 50/60Hz, 1 mn 2.5  
kV  
V
MΩ  
V
V
R.m.s. rated voltage, safe separation  
Isolation resistance @ 500 VDC  
Output voltage @ + IPN, RL = 10 k, TA = 25°C  
Output voltage @ - IPN, RL = 10 k, TA = 25°C  
Output internal resistance  
5002)  
Advantages  
> 1000  
2.5  
1.5  
100  
> 1  
Easy mounting  
VOUT  
Small size and space saving  
Only one design for wide current  
ratings range  
ROUT  
RL  
Load resistance  
kΩ  
High immunity against external  
interference.  
Accuracy - Dynamic performance data  
X
Accuracy @ IPN, TA = 25°C (without offset)  
Linearity 3) (0 .. ± IPN)  
Electrical offset voltage, TA = 25°C  
Hysteresis offset voltage @ IP = 0  
after an excursion of 1 x IPN  
Thermal drift of VOE  
< ± 2  
< ± 1 % of IPN  
< + 2V ± 25 mV  
%
Applications  
ε
VOLE  
VOH  
General purpose inverters  
AC variable speed drives  
Static converters for DC motor drives  
Battery supplied applications  
Uninterruptible Power Supplies  
(UPS)  
< ± 10  
± 1.5  
± 3  
< ± 0.1  
< 5  
mV  
mV/K  
mV/K  
%/K  
µs  
VOT  
typ  
max  
TCε  
Thermal drift of the gain (% of reading)  
Response time @ 90% of IP  
di/dt accurately followed  
G
tr  
Switched-Mode Power Supplies  
(SMPS).  
di/dt  
f
> 50  
DC .. 50  
A/µs  
kHz  
Frequency bandwidth 4) (- 3 dB)  
General data  
TA  
TS  
m
Ambient operating temperature  
- 10 .. + 80 °C  
- 25 .. + 85 °C  
Ambient storage temperature  
Mass  
< 14  
g
5)  
Standards  
EN 50178  
Notes : 1) Conductor terminals are soldered together.  
2) Pollution class 2, overvoltage category III.  
3) Linearity data exclude the electrical offset.  
4)  
Please refer to derating curves in the technical file to avoid excessive  
core heating at high frequency.  
Please consult characterisation report for more technical details and  
application advice.  
5)  
980723/2  
LEM Components  
www.lem.com  

与HY20-P/SP1相关器件

型号 品牌 描述 获取价格 数据表
HY2110 HYCON 1-Cell Lithium-ion/Lithium Polymer

获取价格

HY2110-AB HYCON 1-Cell Lithium-ion/Lithium Polymer

获取价格

HY2110-CB HYCON 1-Cell Lithium-ion/Lithium Polymer

获取价格

HY2110-DB HYCON 1-Cell Lithium-ion/Lithium Polymer

获取价格

HY2111 HYCON 1-Cell Lithium-ion/Lithium Polymer

获取价格

HY2111-DB HYCON 1-Cell Lithium-ion/Lithium Polymer

获取价格