描述
UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTERNAL SWITCHING POWER SUPPLIES

HVP100-33 数据手册

 浏览型号HVP100-33的Datasheet PDF文件第2页 
H HiTRON  
UNIVERSAL INPUT HARMONIC CORRECTION  
AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS  
INTERNAL SWITCHING POWER SUPPLIES HVP100 SERIES  
FEATURES:  
ACCOMMODATE UNIVERSAL AC SOURCES  
MEET IEC 61000-3-2 HARMONIC CORRECTION  
MEET UNIVERSAL SAFETY STANDARDS  
EMI MEET CISPR PUB. 22 CLASS B  
CE MARKING COMPLIANCE  
SPECIFICATION  
INPUT SPECIFICATION  
OUTPUT SPECIFICATION  
Output Voltage: See Ratings Chart.  
Output Current: See Ratings Chart.  
Output Connector: B-S connector.  
Output Wattage: Typ. 100 Watts.  
Line Regulation: Typ. 1.0%.  
Input Voltage: Typ. 90-264Vac with PFC.  
Input Connector: B-S connector.  
Input Frequency: 47-63Hz.  
Inrush Current: Typ. 20A @230Vac (active).  
Input Current: 1.6A@115Vac, 0.6A@230Vac.  
Dielectric Withstand: Meet IEC 60950-1.  
EMI: Meet CISPR PUB. 22 Class B.  
Hold-up Time: Typ. 30mS @ 115Vac & 230Vac.  
Power Fail Signal: Installed.  
Load Regulation: Main VO1 typ. ±1.0%.  
Noise & Ripple: Typ. 1.0% peak to peak.  
OVP: Built-in at main VO1 only.  
Remote Sense: Installed in VO1.  
Adjustability: Available at main O/P VO1.  
Overload Protection (OLP):  
Power Factor Correction: Meet Harmonic Correction  
per IEC 61000-3-2.PF typ. 0.98.  
Earth Leakage: Less than 0.5mA.  
Fully protected against output overload and short circuit.  
OLP set at about 125-150% rating output wattage.  
Consult the factory for OLP setting.  
GENERAL SPECIFICATION  
Efficiency: Typ. 74-79%.  
Switching Frequency: Fixed frequency at 85 or 80K Hz.  
Circuit Topology: PWM fixed frequency forward circuit.  
Transient Response: Output voltage returns in  
less than 3mS following  
Operating Temperature: 0 to +50°C.  
Storage Temperature: -20 to +85°C.  
Temperature Coefficient: Typ. 0.04% /°C.  
Cooling: Free air convection.  
Recommended 20cfm fan cooling for full load.  
Construction: Enclosure box or L-bracket format.  
Power Density: 2.16Watts / Cubic Inch.  
a 25% load change.  
Safety Standard: UL 60950-1/EN 60950-1 Class I.  
Note: Due to requests in market and advances in technology, specifications subject to change without notification.  
For the details of safety approval, please consult the factory.  
-43-  

与HVP100-33相关器件

型号 品牌 描述 获取价格 数据表
HVP100-392 HITRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTER

获取价格

HVP100-393 HITRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTER

获取价格

HVP100-394 HITRON UNIVERSAL INPUT HARMONIC CORRECTION AC-DC OPEN FRAME SINGLE & MULTI-OUTPUT 100 WATTS INTER

获取价格

HVP1007057FB AAC Ultra High Voltage Resistors Up to 5 Gig ohm, 250 Watt and 300 KV DC

获取价格

HVP1007057GB AAC Ultra High Voltage Resistors Up to 5 Gig ohm, 250 Watt and 300 KV DC

获取价格

HVP1007057JB AAC Ultra High Voltage Resistors Up to 5 Gig ohm, 250 Watt and 300 KV DC

获取价格