HT7M2126/27/36/56/76
Interface & Pin Assignment – Stand-alone Mode
Pin #
Function
VSS
Description
1
2
3
4
5
6
7
8
Negative power supply, GND
Positive power supply
VDD
STATUS
TRO
Warm-up/Detecting/Low voltage status
PIR trigger output
FTS
Photo transistor signal
VSS
Negative power supply, GND
Mode & Duration time Selection
No connection (Test pin)
MODE/DT
TP1
TheꢀdefaultꢀconfigurationsꢀforꢀtheꢀStand-aloneꢀModeꢀareꢀasꢀfollow:
1. Continuous trigger mode
2. The TRO pin will output a high pulse signal when an available trigger is detected. The high pulse duration is
determined by the external pull�low resistance of (RA+RT) together with the capacitance of CTꢀwithꢀaꢀfixedꢀvalueꢀ
ofꢀ0.22μF.
External capacitance CT = 0.22uF*, VDD = 3.3V
RA+RT Resistance (Ω)
1.8K
2.2K
2.7K
3K
3.3K
3.6K
3.9K
TRO output duration time *
3sec.
10sec.
38sec.
1mins.
3mins.
5mins.
10mins.
Note: (a) The TRO output high duration is 30 seconds in default if there is no external capacitor CT.
(b) The value of the resistance, capacitance and TRO output duration time in the above table is used for ref�
erence only.
3. The STATUS pin will output various types of signals corresponding to the device in the warm�up mode, standby
detection mode or low operating voltage mode where the operating voltage is lower than 2.7V respectively.
(a) Warm-upꢀmode:ꢀAꢀtoggleꢀoutputꢀwithꢀaꢀfrequencyꢀofꢀ2.5HzꢀwillꢀbeꢀoutputꢀonꢀtheꢀSTATUSꢀpin.
STATUS
(f=2.5Hz)
(b) Standy detection mode: A signal composed of a low pulse of 10ms and a high pulse of 4s will continuously
be output on the STATUS pin.
4s
4s
STATUS
10ms
10ms
10ms
Output signal
(c)ꢀLowꢀvoltageꢀmode:ꢀTwoꢀlowꢀpulsesꢀwithꢀaꢀwidthꢀofꢀ10msꢀwillꢀfirstꢀbeꢀoutputꢀonꢀtheꢀSTATUSꢀpinꢀandꢀtheꢀ
time duration between these two low pulses is 80ms. Then a high pulse with the width of 1 second will con�
secutively be output. Such an output signal will continuously be output on the STATUS pin.
1s
1s
1s
STATUS
80ms
80ms
80ms
10ms
10ms
Output signal
10ms
10ms
10ms
10ms
Rev. 1.20
3