FEATURES:  
DESCRIPTION:  
Detects ionizing radiation pulses  
Tested/certified detection threshold level  
Adjustable circumvention period  
100% testable with built-in test  
Detection threshold adjustability  
Single +5V operation  
Maxwell Technologies’ HSN-500 radiation-hardened Hybrid  
Nuclear Event Detector (NED) senses ionizing radiation pulses  
generated by a nuclear event, such as the detonation of a nuclear  
weapon, and rapidly switches its output from the normal high  
state to a low state with a propagation delay time of less than 20  
ns. The active low Nuclear Event Detection signal (NED) is used  
to initiate a wide variety of circumvention functions, thus prevent-  
ing upset and burnout of electronic components. The NED output  
is also used to initiate both hardware and software recovery. This  
high-speed, 14-pin hybrid detector is used in electronic systems  
as a general-purpose circumvention device to protect memory,  
stop data processing, and drive power supply switches as well as  
signal clamps.  
Designed-in radiation hardness  
Compliant to MIL-PRF-38534 Class H  
1
Flat pack (F) or DIP (L) packages  
RADIATION HARDNESS  
CHARACTERISTICS  
The HSN-500 is designed to operate through three critical envi-  
ronments: ionizing dose rate [1012 rad(Si)/s], gamma total dose  
[106 rad(Si)], and neutron fluence [5 x 1013 n/cm2]. In addition, the  
device is designed to function throughout the transient neutron  
pulse. The hybrids discrete design ensures a controlled response  
in these radiation environments as well as immunity to latchup.  
The detection level and functionality of a sample of each HSN-  
500 production lot are tested in an ionizing dose rate environ-  
ment. A certificate is provided reporting the test results for the  
production lot.  
Dose Rate (operate-through): 1 x 1012 rad(Si)/sec  
Total Dose: 1 x 106 rad(Si)  
Neutron Fluence: 5 x 1013 n/cm2  
Approximate Detection Range: 2 x 105 - 2 x 107 rad(Si)/sec  
Maxwell Technologies Specified, Controlled, and Tested  
The detection threshold of the HSN-500 is adjustable within the  
range of 2 x 105 rad(Si)/s to 2 x 107 rad(Si)/s. This detection level  
can be preset by Maxwell or adjusted by the user. Less than a  
30% variation in detection threshold can be expected over the  
entire operating temperature range.  
1. Manufactured for Maxwell Technologies by Teledyne Micoelectronic  
Technologies to MIL-PRF-38534, Class H, no RHA  
01.7.05 Rev 3  
1
All data sheets are subject to change without notice  
(858) 503-3300 - Fax: (858) 503-3301 - www.maxwell.com  
©2005 Maxwell Technologies  
All rights reserved.  

与HSN500L相关器件

型号 品牌 获取价格 描述 数据表
HSN-500L MAXWELL

获取价格

Nuclear Event Detector
HSNA1 MMD

获取价格

6.0mm x 3.5 mm x1.2mm Ceramic Package
HSNA3 MMD

获取价格

6.0mm x 3.5 mm x1.2mm Ceramic Package
HSNB1 MMD

获取价格

6.0mm x 3.5 mm x1.2mm Ceramic Package
HSNB3 MMD

获取价格

6.0mm x 3.5 mm x1.2mm Ceramic Package
HSNC1 MMD

获取价格

6.0mm x 3.5 mm x1.2mm Ceramic Package
HSNC1-11.999MHZ MMD

获取价格

Crystal Filter, ROHS COMPLIANT, CERAMIC PACKAGE-4
HSNC1-12.000MHZ MMD

获取价格

Crystal Filter, ROHS COMPLIANT, CERAMIC PACKAGE-4
HSNC1-12.000MHZ-T MMD

获取价格

Crystal Filter, ROHS COMPLIANT, CERAMIC PACKAGE-4
HSNC3 MMD

获取价格

6.0mm x 3.5 mm x1.2mm Ceramic Package