■Specifications
Operating temperature range
-40
-40
ç
ç
to +75
to +75
ç
ç
Max. input power
Fiber type
250 mW
SMF
Rating
Storage temperature range
Characteristic
Attenuation
Test Method (Conforms with Telcordia GR-910-CORE)
Specification
Refer to the various types of attenuation tolerance (the previous page).
60 dB min.
Measurement at a point within the wavelength of 1310 30
nm and a point within the wavelength of 1550 30 nm.
Return loss
Power
: 250mW(LD)
: 1470nm
After / during test, changing in attenuation(fluctuation)shall be less than
0.1dB.
Rated input power
Wavelength
Duration
: 100 hours
Temperature
Duration
: -5ç to 50ç
: 182.5 hours
: 15% to 90%
: -40ç to 75ç
Controlled Operating
Environment
Humidity
Temperature
Uncontrolled Operating
Environment
Period of 1 cycle : 8 hours
Number of cycles : 21
Low-Temperature Exposure and Thermal Shock
Temperature
Duration
:
:
23
ç
■ 40
ç
■
-
40
ç ■ 23ç
2.1h
72 h 5 min. minimum
1) After test, change in attenuation(fluctuation)and return loss shall be
1) as follows.
High-Temperture Exposure and Thermal Shock
Non-Operating
Environment
Temperature
Duration
:
:
23
ç
■ 70
ç ■ 70ç ■ 23ç
1) • Attenuation(fluctuation) : within 0.5 dB
1.6h
72 h 5 min. minimum
1) • Return loss
: 60 dB min.
High Relative Humidity Exposure
2) No breakage, crack or dislocation of components.
Temperature
Duration
:
:
23
ç
■ 40
ç
■
40ç ■ 23ç
0.6h
96 h 0.6h
Humidity
: 90% to 95%
: -10ç to 65ç
Temperature
Humidity/Condensation
Cycling Test
Period of 1 cycle : 12 hours
Humidity
: 90% to 100%
Number of cycles : 14
Temperature
Duration
: 43ç
Water Immersion
Vibration
: 168 hours
: PH 5.5
Solution
Vibration frequency range : 10 to 55 Hz
Maximum amplitude: 1.52 mm
Duration
: 2 hours in each of 3 directions
1) After /during test, change in attenuation(fluctuation)and return loss
1) shall be as follows.
1) • Attenuation(fluctuation) : within 0.5 dB
Bend angle
Load
: 90°
Side Pull Load
: 1.25 kg
1) • Return loss
: 60 dB min.
2) No breakage, crack or dislocation of components.
1) After test, change in attenuation(fluctuation)and return loss shall be
1) as follows.
1) • Attenuation(fluctuation) : within 0.5 dB
Cable Retention
Durability
Load
: 2 kg
Insertion/withdrawal cycles : 200
Drop onto a concrete floor from a height of 1.8 m.
Cycles: 8 times in each of 3 directions
1) • Return loss
: 60 dB min.
Impact Test
2) No breakage, crack or dislocation of components.
■Materials and Dimensions
Serial No.
9.4
Component
Body
Material
Zinc alloy
Zirconia
Zirconia
Ferrule
Split sleeve
35.5
5-23,OSAKI 5-CHOME,SHINAGAWA-KU,TOKYO 141-8587,JAPAN
PHONE: 81-3-3491-9741, FAX: 81-3-3493-2933
http://www.hirose.com
http://www.hirose-connectors.com
2