150W Single Output with PFC Function
HRP-150N series
SPECIFICATION
MODEL
HRP-150N-36
HRP-150N-12
HRP-150N-24
HRP-150N-48
DC VOLTAGE
12V
24V
36V
48V
RATED CURRENT
CURRENT RANGE
RATED POWER
13A
6.5A
4.3A
3.3A
0 ~ 6.5A
0 ~ 4.3A
154.8W
200mVp-p
28.8 ~ 39.6V
1.5%
0 ~ 3.3A
158.4W
240mVp-p
40.8 ~ 55.2V
1.5%
0 ~ 13A
156W
156W
RIPPLE & NOISE (max.) Note.2 120mVp-p
150mVp-p
OUTPUT
VOLTAGE ADJ. RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
10.2 ~ 13.8V
21.6 ~ 28.8V
1.5%
1.5%
0.2%
0.2%
0.2%
0.3%
LOAD REGULATION
SETUP, RISE TIME
0.5%
0.5%
0.5%
0.5%
3000ms, 50ms/230VAC
3000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC
16ms/115VAC at full load
120 ~ 370VDC
VOLTAGE RANGE
Note.4 85 ~ 264VAC
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
47 ~ 63Hz
PF>0.95/230VAC
PF>0.98/115VAC at full load
88%
INPUT
89%
89%
88%
1.7A/115VAC
35A/115VAC
<1mA / 240VAC
0.9A/230VAC
70A/230VAC
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
Normally works within 105 ~ 200% rated output power for more than 5 seconds and then shut down o/p voltage, re-power
on to recover
OVERLOAD
Constant current limiting for output power >280% rated for more than 5 seconds and then shut down o/p voltage, re-power
on to recover
PROTECTION
14.4 ~ 16.8V
30 ~ 34.8V
41.4 ~ 48.6V
57.6 ~ 67.2V
OVER VOLTAGE
Protection type : Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +70℃ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
ENVIRONMENT
-50 ~ +85℃, 10 ~ 95% RH
0.04%/℃ (0 ~ 50℃)
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
OPERATING ALTITUDE Note.6 5000 meters
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
UL62368-1, TUV EN62368-1, EAC TP TC 004, AS/NZS 62368.1 approved
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
Parameter
Standard
Test Level / Note
Conducted
EN55032
Class B
Class B
Class A
-----
Radiated
EN55032
Harmonic current
Voltage Flicker
EN61000-3-2
EN61000-3-3
EMC EMISSION
SAFETY &
EMC
EN55035 , EN61000-6-2(EN50082-2)
(Note 5)
Parameter
ESD
Standard
Test Level / Note
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
EN61000-4-8
Level 3, 8KV air; Level 2, 4KV contact
Level 3, 10V/m
RF field
EFT/ Burst
Surge
Level 3, 2KV
EMC IMMUNITY
Level 4, 4KV/Line-FG; 2KV/Line-Line
Level 3, 10V
Conducted
Magnetic Field
Level 4, 30A/m
95% dip 0.5 periods, 30% dip 25 periods,
95% interruptions 250 periods
Voltage Dips and Interruptions
EN61000-4-11
578.15K hrs min. Telcordia TR/SR-332 (Bellcore) ; 221.71K hrs min. MIL-HDBK-217F (25℃)
MTBF
OTHERS
DIMENSION
PACKING
159*97*38mm (L*W*H)
0.54Kg; 24pcs/12.96Kg/0.9CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
NOTE
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on
a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to
perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
※ Product Liability Disclaimer:For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
File Name:HRP-150N-SPEC 2020-11-03