DC-HVDC Converter
HRL30 Series
Environmental
Characteristic
Minimum
Typical
Maximum
+70
Units
°C
Notes & Conditions
Operating (Case) Temperature
Storage Temperature
Humidity
-40
-55
Consult factory for extended operating temperature
+125
95
°C
%RH
Non-condensing
Cooling
Natural convection
Safety Approvals
Safety Agency
Safety Standard
Notes & Conditions
*UL pending
UL
EN 60950 and EN62368
CE
CE Directive, *RoHs and LVD
RoHS 2 and 3 Directive (2011/65/EU)
*Pending
RoHS
*Where applicable
Signals
Characteristic
-VIN
Pin
1
Function
Input Ground
Description
Power Ground
2
Input: Remote Disable
Output: Voltage Reference
Signal Ground
Open or No Connect turns unit ON.
+5V +/-2%
Ground connection turns unit OFF
DISABLE
VREF
3
SGND
VPGM
VMON
IPGM
4
Signal Ground
5
Input: Voltage Programming
Output: Voltage Monitor
Input: Current Programming
Output: Current Monitor
N/A
0V to +5V signal programs Vout from
0V to +5V output measures 0 to 100%
0V to +5V signal programs Iout from 0
0V to +5V output measures 0 to 100%
0 to 100%, Z=100kohm.
6
Vout, 1.5% accuracy. 1.5%
to 100%, Z=100kohm.
7
8
Iout, 1.5% accuracy. 1.5%
IMON
N/C
9
N/C
10
11
12
13
14
N/A
N/C
N/A
+VIN
Input: 24Vin
Power Input
HVOUT
HVRTN
HV Output
High Voltage Output
High Voltage Return
HV Return
www.xppower.com