HO 40 .. 150-NP series
HO-NP series: name and codification
HO family products may be ordered on request 1) with a dedicated setting of the parameters as described below
(standards products are delivered with the setting 0100 according to the table).
HO-NP-XXXX
Internal reference
Response time
EEPROM Control
Over current detection (× IPN
)
0
1
2
3
4
2.5 V
1.65 V
1.5 V
0.5 V
0
1
2
3.5 µs
2.5 µs
6 µs
0
1
YES
NO
0
1
2
3
4
5
6
7
2.93
3.59
3.99
4.77
5.19
5.76
1.68
2.35
External Vref only
Standards products are:
- HO 40-NP-0100
- HO 60-NP-0100
- HO 120-NP-0100
- HO 150-NP-0100
HO-NP series: output compatibility with HAIS Series
Vout - Vout
Vout - Vout
@ IPN (V)
Reference
I
PN (A)
I
PM (A)
I
PM / IPN
Reference
I
PN (A)
I
PM (A)
I
PM / IPN
@ IPN (V)
HO 40-NP
HO 60-NP
HO 120-NP
HO 150-NP
40
60
100
150
300
375
2.5
2.5
2.5
2.5
0.8
0.8
0.8
0.8
HAIS 50-TP
50
150
3
3
0.625
0.625
120
150
HAIS 100-TP
100
300
The HO-NP gives the same output levels as the HAIS-TP referring to the HAIS nominal currents.
This allows easier replacement of HAIS by HO-NP in existing applications.
Note: 1) For dedicated settings, minimum quantities apply, please contact your local LEM support.
Page 9/12
25July2014/Version 1
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
www.lem.com