HMU Series
Basic pressure sensors
FEATURES
· 100 mbar to 10 bar, 1 to 150 psi
absolute, gage or differential pressure
· Increased media compatibility1
· Wide operating temperature range
· SIL and DIP housings
· RoHS compliant
· Quality Management System according
to ISO 13485:2003 and ISO 9001:2008
MEDIA COMPATIBILITY1,2
High pressure port: To be used with gases and
liquidswhich are compatible with the wetted
materials (high temperature polyamide, ceramic
AL2O3, epoxy, fluorosilicone, glass, silicon).
Low pressure port: To be used with non-corrosive,
non-ionic working fluids such as clean dry air, dry
gases and the like.
SPECIFICATIONS
ELECTRICAL CONNECTION
Maximum ratings
Supply voltage VS
... 12 VDC
Environmental
+Vs
Temperature ranges
Operating
4
-40 ... +85 °C (-40 ... +125 °C)7
-40 ... +125 °C
Storage3
Humidity limits (non-condensing)
...95 %RH8
(100 % condensing or direct liquid media on high pressure port1)
-Vout
1
+Vout
3
Vibration
max. 10 g, 10...2000 Hz, random
(EN 60068-2-64)
Mechanical shock
max. 50 g, 11 ms
(EN 60068-2-27)
Lead solder temperature
max. 270 °C
(JESD22-B106D)
2
GND
E / 11801 / B
1/14
www.first-sensor.com
www.sensortechnics.com