HMC600LP4 / 600LP4E
v02.0909
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Package Information
Part Number
Package Body Material
Lead Finish
MSL Rating
MSL1 [1]
Package Marking [3]
H600
XXXX
HMC600LP4
Low Stress Injection Molded Plastic
Sn/Pb Solder
H600
XXXX
MSL1 [2]
HMC600LP4E
RoHS-compliant Low Stress Injection Molded Plastic
100% matte Sn
[1] Max peak reflow temperature of 235 °C
[2] Max peak reflow temperature of 260 °C
[3] 4-Digit lot number XXXX
Pin Descriptions
12
Pin Number
Function
Description
Interface Schematic
These pins are not connected internally; however,
this product is specified with these pins connected
to RF/DC ground.
1, 6, 7-13,
15, 18-24
N/C
2, 6
Vcc1, Vcc2
Bias supply. Connect supply voltage to both pins.
RF Input pins. Connect RF to INP, and AC couple
INN to ground for single-ended operation.
3, 4
INP, INN
Connect to 0V for normal operation. Applying voltage
>0.8 x Vcc will initiate a power saving shutdown mode.
14
PWD
To ensure proper start-up apply the power-up sequence
shown in the “Power-Up Timing Diagram” attached to the
application circuit.
VSET input in controller mode. Short this
pin to LOGOUT for detector mode.
16
17
VSET
Logarithmic output that converts the input power
to a DC level in detector mode. Short this pin to
VSET for detector mode.
LOGOUT
Package
Base
GND
Exposed paddle must be connected to RF and DC ground.
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
12 - 7