Symbol
Type
Function
Alert: It has multiple functions, such as CRC error flag, Command and Address Parity
error flag, as an Output signal. If there is an error in CRC, then ALERT_n goes LOW for
the period time interval and goes back HIGH. If there is an error in Command Address
ALERT_n
Output Parity Check, then ALERT_n goes LOW for a relatively long period until on going DRAM
internal recovery transaction is complete. During Connectivity Test mode, this pin
functions as an input.
Using this signal or not is dependent on the system.
RFU
NC
Reserved for Future Use. No on DIMM electrical connection is present.
No Connect: No on DIMM electrical connection is present.
VDD1
Supply
Supply
Supply
Supply
Supply
Supply
Supply
Power Supply: 1.2 V +/- 0.06 V
Ground
VSS
DRAM Activating Power Supply: 2.5V (2.375V min , 2.75V max)
Power Supply for termination of Address, Command and Control, VDD/2.
12V supply not used on UDIMMs.
VPP
VTT2
12V
Power supply used to power the I2C bus on the SPD-TSE
Reference voltage for CA
VDDSDP
VREFCA
Note:
1. For PC4 VDD 1.2V. For PC4L VDD is TBD.
2. For PC4 VTT is 0.60V. For PC4L VTT is TBD.
Rev. 1.5 / Jan.2020