240W Single Output Switching Power Supply
HLG-240H series
Features :
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by free air convection
OCP point adjustable through output cable or internal potential meter
Suitable for LED lighting and moving sign applications
IP67 / IP65 design for indoor or outdoor installations
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
3 years warranty
110
F
SELV
IP65 IP67
HLG-240H-12
A
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated. Output voltage and constant current level can be adjusted through internal potential meter.
B : IP67 rated. Constant current level adjustable through output cable.
C : Terminal block for I/O connection. Output voltage and constant current level can be adjusted through internal
potential meter.
SPECIFICATION
HLG-240H-36
HLG-240H-42
MODEL
HLG-240H-12
HLG-240H-15
HLG-240H-20
HLG-240H-24
HLG-240H-30
HLG-240H-48
HLG-240H-54
36V
42V
DC VOLTAGE
12V
15V
20V
24V
30V
48V
54V
18 ~ 36V
6.7A
21 ~ 42V
5.72A
CONSTANT CURRENT REGION Note.4 6 ~12V
7.5 ~ 15V
15A
10 ~ 20V
12A
12 ~ 24V
10A
15 ~ 30V
8A
24 ~ 48V
5A
27 ~ 54V
4.45A
RATED CURRENT
RATED POWER
16A
241.2W
250mVp-p
240.2W
250mVp-p
192W
225W
240W
240W
240W
200mVp-p
240W
250mVp-p
240.3W
350mVp-p
RIPPLE & NOISE (max.) Note.2 150mVp-p
150mVp-p
150mVp-p
150mVp-p
33.5 ~ 38.5V 39 ~ 45V
VOLTAGE ADJ. RANGE Note.6 11.2 ~ 12.8V 14 ~ 16V 18.6 ~ 21.4V 22.4 ~ 25.6V 28 ~ 32V
Can be adjusted by internal potential meter or through output cable
44.8 ~ 51.2V 50 ~ 57V
OUTPUT
CURRENT ADJ. RANGE
8 ~ 16A
VOLTAGE TOLERANCE Note.3 2.5%
3.3 ~ 6.7A
1.0%
2.86 ~ 5.72A
7.5 ~ 15A
2.0%
6 ~ 12A
1.0%
5 ~ 10A
1.0%
4 ~ 8A
1.0%
0.5%
0.5%
2.5 ~ 5A
1.0%
2.23 ~ 4.45A
1.0%
0.5%
0.5%
1.0%
0.5%
0.5%
0.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
POWER FACTOR
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
Note.8 2.0%
1.5%
1.0%
0.5%
0.5%
Note.9 2500ms, 80ms at full load 230VAC /115VAC
15ms at full load 230VAC /115VAC
Note.5 90 ~ 305VAC
47 ~ 63Hz
127 ~ 431VDC
PF0.95/230VAC
PF 0.98/115VAC at full load and rated output voltage
92% 93%
2A / 230VAC
PF 0.9 at 65 ~ 100% load
INPUT
EFFICIENCY (Typ.)
AC CURRENT
90%
93%
93.5%
94%
90%
93%
93%
4A / 115VAC
INRUSH CURRENT(Typ.)
LEAKAGE CURRENT
COLD START 75A/230VAC
<0.75mA / 277VAC
95 ~ 108%
OVER CURRENT
Note.4
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT
OVER VOLTAGE
32.5 ~ 36.5V 40 ~ 48V
46 ~ 50V
53 ~ 62V
59 ~ 65V
13.5 ~ 16V
Protection type : Shut down and latch off o/p voltage, re-power on to recover
95 (TSW1)
16.5 ~ 19.5V 22 ~ 26V
26 ~ 33V
PROTECTION
5
105
5
(TSW1)
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
-30 ~ +60 @ full load ; +70 @ 60% load (Refer to derating curve)
20 ~ 95% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +80 , 10 ~ 95% RH
ENVIRONMENT
0.03%/ (0 ~ 50
)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS Note.7
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
UL1012, TUV EN61347-1, EN61347-2-13 independent (except for HLG-240H C type), UL60950-1, UL8750, TUV EN60950-1, IP65 or IP67 approved
I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC
SAFETY &
EMC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B
EMI CONDUCTION & RADIATION
HARMONIC CURRENT
EMS IMMUNITY
MTBF
Compliance to EN61000-3-2 Class C ( 50% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11; ENV50204, EN61547, EN55024, heavy industry level (surge 4KV), criteria A
207.9Khrs min. MIL-HDBK-217F (25
)
244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B)
1.3Kg; 12pcs/16.6Kg/0.74CUFT(HLG-240-Blank/A/B)
251*68*38.8mm (L*W*H)(HLG-240H-C)
OTHERS
NOTE
DIMENSION
1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240-C)
PACKING
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Constant current operation region is within 50% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
6. Type A and type C only.
7. Safety and EMC design refer to EN60598-1, subject 8750(UL), CNS15233, GB7000.1, FCC part18.
8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.