HK25A
HK25A
HK25A Specifications
ꢀ
MODEL
HK25A-3
HK25A-5
HK25A-12
HK25A-15
HK25A-24
ITEMS/UNITS
Voltage Range
(*2)
V
AC85-132 or DC110-175
Frequency
(*2) Hz
47-440
Input Efficiency (typ)
(*1)
(*1)
%
A
70
72
76
77
80
Current (100VAC)(typ)
0.5
0.6
Inrush Current (100VAC)(typ) (*3)
Nominal Voltage
A
15
VDC
A
3.3
5.0
5
12
15
1.7
24
1.1
Maximum Current
5.0
25.0
2.1
Maximum Power
W
16.5
25.2
25.5
60
26.4
96
Maximum Line Regulation
(*4) mV
(*5) mV
20
40
48
96
Output Maximum Load Regulation
120
150
Temperature Coefficient (typ) (*9)
Maximum Ripple & Noise
1% at 0℃ to +50℃
mVp-p
120
150
Hold-up Time (typ)
Voltage Adjustable Range
Over Current Protection
Function Over Voltage Protection
Series Operation
(*1) ms
20
±10%
(*6)
(*7)
>105%
115% to 135%
Possible
HK-A
Operating Temperature
Storage Temperature
Operating Humidity
Environment Storage Humidity
Vibration
(*8)
℃
℃
%RH
%RH
0 to +50 (100%), 60 (50%)
-30 to +85
30 - 90
10 - 95
10-55Hz (sweep 1 min) less than 19.6m/s² X, Y, Z 1 h each
Less than 196.1m/s²
Shock
Cooling
Convection Cooled
Input-Chassis, Input-Output : 2kVAC (20mA)
Output-Chassis : 500VAC (100mA) for 1min
Withstand Voltage
Isolation
(*10)
Isolation Resistance
More than 100MΩ at 25℃ and 70% RH Output-FG 500VDC
Approved by UL60950-1, CSA C22.2 No.60950. Built to meet DENAN.
(HK25A-3 is built to meet safety standards.)
Safety Standards
Standards
EMI
Built to meet FCC class B,VCCI-B
230
Weight
Mechanical
g
Size (W x H x D)
mm
28 x 68 x 95 (Refer to outline drawing)
(*1) At 100VAC & maximum output power,Ta = 25 ℃ .
(*2) For cases where conformance to various safety specs (UL, CSA) are required to be
described as 100-120VAC, 50/60Hz on name plate.
●
Recommended EMC Filter
(*3) Typical value on cold start, Ta=25℃.
(*4) From 85 to 132VAC or 110 to 175VDC, constant load.
(*5) From no load to full load, constant input voltage.
(*6) Current limiting with automatic recovery.
Avoid to operate over load or dead short for more than 30 seconds.
RSEL-2001W
Please refer to "TDK-Lambda
EMC Filters" catalog.
(*7) Inverter shut down, manual reset.
(*8) At standard mounting (vertical).
(*9) Constant input voltage & load.
(*10) Refer to instruction manual for testing procedure.
OUTPUT DERATING
Without cover
With cover
120
100
80
60
40
20
0
100
B
Mounting A
90
80
70
60
50
40
A
Mounting B
PCB
C, D
Mounting C, D
(A)
(B)
(C)
(D)
(E)Don't use
20
Recommended standard mounting method is (A). (B), (C), (D)
are also possible, but please use within the range of derating.
Please do not use (E), where the PCB will be on the top side
and heat will be trapped inside the unit.
0
10 20 30 40 50 60 70
0
10 20 30 40 50 60 70
Ta (℃)
Ta (℃)
・All specifications are subject to change without notice.
A-80