Performance Specifications
1
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause catastrophic damage to the device. Limits apply to each
parameter in isolation, all other parameters having values within the recommended operating conditions. It should not be
assumed that limiting values of more than one parameter can be applied to the product at the same time. Exposure to the absolute
maximum ratings for extended periods can adversely affect device reliability.
Parameter
Symbol
Minimum
Maximum
Units
Notes
Storage Temperature
TS
-40
+85
°C
-
Lead Soldering Temperature/Time
Input Voltage Swing
-
-
+240/10
°C/s
V
VIN
0
0
0
2
2
Power Supply Voltage
VCCT/VCCR
RH
+6
95
V
Relative Humidity (Non-Condensing)
%
RecommendedOperatingEnvironment
Parameter
Symbol
Minimum
Maximum
Units
Notes
Power Supply Voltage
VCC
4.75
5.25
V
-
Ambient Operating Temperature
Airflow
TAOP
0
2
+70
°C
3
3
4
m/s
mV p-p
Power Supply Noise Tolerance
PSNT
50
Transmitter Section
(T = 0°C to +70°C, V = 4.75 V to 5.25 V)
A
cc
Parameter
Symbol
Minimum
Typical
Maximum
Units Notes
lce
Dl
PO
Output Center Wavelength
Output Spectral Width (RMS)
Average Optical Output Power
Extinction Ratio
1270
-
-
1360
4.0
-3
nm
nm
dBm
dB
-
3
-
-9.5
8.2
-5
10
5
ER
-
6
Output Eye
Compliant with Bellcore GR-253-CORE and ITU recommendation G.957
Figure 24
7
Supply Current
ICCT
-
60
100
mA
W
Power Dissipation
PDISS
-
0.29
0.53
1100
1800
VCCT
3.5
Data Input - Single Ended
Data Input - Differential
Transmitter Disable
VIN p - p
VIN p - p
VTXD
200
400
4
-
-
-
-
mV
mV
V
8
Figure 2b
Transmitter Enable
VTXE
VEE
V
Notes:
1. Notnecessarilyappliedtogether. Doesnotguaranteeoperationundertheseconditions.
2. Single ended amplitude - see Figure 2 for definition.
3. With recommended metal shield in place and with 2 m/s forced airflow around the transceiver.
4. Between 10 Hz and 10 MHz and using power supply filter circuit as recommended.
5. Output Power is power coupled into a single mode fiber.
6. Measured for TIA/EIA-526-4A.
7. The power supply current varies with temperature. Maximum current is specified at V = Maximum @ maximum temperature (not including
CC
termination’s) and end of life.
8. Driven into 50 ohm load, measured single-ended.
16