Dynamic Characteristics -40 °C to +85 °C; 4.75 V ≤ Supply Voltage ≤ 5.25 V; R
otherwise specified
= 511 W, C
= 5 pF unless
LOAD
LOAD
Parameter
Symbol Min
Typ2
3.3
Max
6.3
Units
Conditions
Reference
Rise/Fall Time 10% to 90%
Pulse Width Distortion
tr, tf
ns
ns
PR = 100 µW peak
PR = 150 µW peak
Figure 17
PWD
0.4
2.5
Note 8,
Figure 16
Overshoot
2
%
PR = 5 µW peak,
tr = 1.5 ns
Note 9
Bandwidth (Electrical)
BW
125
MHz
-3 dB Electrical
Note 10
Bandwidth - Rise Time Product
0.41
Hz • s
Notes:
1. 2.0 mm from where leads enter case.
2. Typical specifications are for operation at T = +25 °C and V = +5 V dc.
A
CC
3. For 200 µm HCS fibers, typical responsivity will be 6 mV/mW. Other parameters will change as well.
4. Pin #2 should be ac coupled to a load ³ 510 ohm. Load capacitance must be less than 5 pF.
5. Measured with a 3 pole Bessel filter with a 75 MHz, -3 dB bandwidth. Recommended receiver filters for various bandwidths are provided in
Application Bulletin 78.
6. Overdrive is defined at PWD = 2.5 ns.
7. D is the effective diameter of the detector image on the plane of the fiber face. The numerical value is the product of the actual detector diameter
and the lens magnification.
8. Measured with a 10 ns pulse width, 50% duty cycle, at the 50% amplitude point of the waveform.
9. Percent overshoot is defined as:
VPK − V100%
x100%
V100%
10. The conversion factor for the rise time to bandwidth is 0.41 since the HFBR-24x6 has a second order bandwidth limiting characteristic.
0.1 µF
+5 V
10 Ω
6
30 pF
2
POST
AMP
LOGIC
OUTPUT
3 & 7
R
LOADS
500 Ω MIN.
Figure 14. Recommended ac Coupled Receiver Circuit. (See AB 78 and AN 1038 for more information.)