描述
Energy Efficiency Level VI

HEMG76-S120550-8 数据手册

 浏览型号HEMG76-S120550-8的Datasheet PDF文件第2页 
H HiTRON  
Universal input AC-DC Medical and ITE application external desktop  
switching adapter 66-72 Watts green power single output HEMG76 series  
Features  
Energy Efficiency Level VI  
Medical and ITE application  
Wide operating temperature range and  
high efficiency  
Class I and Class II construction  
CE marking compliance  
Specification  
Input  
Protection  
Input Voltage  
Input Frequency  
Input Current  
90-264VAC  
Over Load  
Typical set at about 125-130% of  
rating output wattage  
NTC  
47-63Hz  
Typical 1.2A at 115VAC  
Typical 0.75A at 230VAC  
Typical 13.1Arms at 230VAC  
3 pole IEC320-C14(DT7)  
3 pole IEC320-C6(DT7L)  
2 pole IEC320-C8(DT8)  
Less than 0.21 mA or better  
Less than 0.09mA or better  
Less than 0.2W  
Over Temperature  
General  
Efficiency  
Inrush Current  
Typical 88-90% (depending on model)  
65KHz  
Input Connector  
Switching Frequency  
Dielectric Withstand  
Circuit Topology  
Transient Response  
IEC60601-1 and IEC60950-1  
Flyback circuit  
Earth Leakage Current  
Enclosure Leakage  
No Load Power  
Output  
Output voltage returns in less than  
1mS following a 25% load change  
4.3-4.7W / Cubic inch  
Desktop Format  
Power Density  
Construction  
Output Connector/Plug  
Line Regulation  
Load Regulation  
Total Regulation  
Noise & Ripple  
Adjustability  
Optional  
Environmental  
Operating Temperature  
Storage Temperature  
Cooling  
Typical 1%  
-25°C to +40°C  
-40°C to +85°C  
Convection-cooled  
5000m  
Typical ±3%  
Typical ±3%  
Typical 1% peak to peak  
Factory set  
Operating Altitude  
Operating Humidity  
Storage Humidity  
10-95% RH, non-condensing  
5-95% RH  
Hold-up Time  
Typical 19mS at 115VAC  
Typical 96mS at 230VAC  
Safety/EMC  
Emissions  
EN55011 & EN55022 FCC Class B  
IEC60601-1 Class I and Class II  
IEC60950-1 Class I and Class II  
Protection  
Over Voltage  
Built-in  
Built-in  
Safety Standard  
Over Current  
Notes:  
(1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.  
(2) Load regulation is measured at 115VAC or 230VAC in percentage to indicate the change in output voltage as the load varied from half load to full load ( %).  
(3) The exact obtainable load regulation depends upon the output cord selected and load current.  
(4) Due to requests in market and advances in technology, specifications subject to change without notice  
V.1 Edited on March 29, 2016  
-1-  

与HEMG76-S120550-8相关器件

型号 品牌 描述 获取价格 数据表
HEMG76-S240300-7 HITRON Energy Efficiency Level VI

获取价格

HEMG76-S240300-7L HITRON Energy Efficiency Level VI

获取价格

HEMG76-S240300-8 HITRON Energy Efficiency Level VI

获取价格

HEMG76-S480150-7 HITRON Energy Efficiency Level VI

获取价格

HEMG76-S480150-7L HITRON Energy Efficiency Level VI

获取价格

HEMG76-S480150-8 HITRON Energy Efficiency Level VI

获取价格