85 ~ 100W Ultra Slim Step Shape DIN Rail
HDR-100 series
SPECIFICATION
HDR-100-12 HDR-100-12N
HDR-100-15N HDR-100-24 HDR-100-24N HDR-100-48 HDR-100-48N
HDR-100-15
MODEL
12V
24V
48V
15V
DC VOLTAGE
7.1A
0 ~ 7.1A
85.2W
7.5A
0 ~ 7.5A
90W
6.5A
0 ~ 6.5A
97.5W
3.83A
0 ~ 3.83A
92W
4.2A
0 ~ 4.2A
100.8W
1.92A
0 ~1.92A
92.2W
2.1A
0 ~ 2.1A
100.8W
6.13A
0 ~ 6.13A
92W
RATED CURRENT
CURRENT RANGE
RATED POWER
RIPPLE & NOISE (max.) Note.2
120mVp-p
12 ~ 13V
12~ 13.8V
ꢅ2.0%
ꢅ1.0%
ꢅ1.0%
150mVp-p
24 ~ 25.5V
21.6 ~ 29V
ꢅ1.0%
ꢅ1.0%
240mVp-p
48 ~ 48.7V
43.2 ~ 55.2V
ꢅ1.0%
ꢅ1.0%
120mVp-p
15 ~ 17V
13.5 ~ 18V
ꢅ1.0%
ꢅ1.0%
ꢅ1.0%
Pass LPS
Non LPS
OUTPUT
VOLTAGE ADJ.
RANGE
VOLTAGE TOLERANCE Note.3
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
ꢅ1.0%
ꢅ1.0%
500ms, 60ms/230VAC
500ms, 60ms/115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
30ms/230VAC
85 ~ 264VAC (277VAC operational )
47 ~ 63Hz
12ms/115VAC at full load
120 ~ 370VDC (390VDC operational )
INPUT
88%
90%
90%
89%
AC CURRENT (Typ.)
INRUSH CURRENT (Typ.)
3A/115VAC
COLD START 35A/115VAC
1.6A/230VAC
70A/230VAC
HDR-100 : 102 ~ 110% rated output powerꢀ;ꢀHDR-100-xxN : 105 ~ 150% rated output powerꢀ
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVERLOAD
Note.4
PROTECTION
14.2 ~ 16.2V
18.8 ~ 22.5V
30 ~ 36V
56.5 ~ 64.8V
OVER VOLTAGE
WORKING TEMP.
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +70ꢄ (Refer to "Derating Curve")
20 ~ 90% RH non-condensing
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
-40 ~ +85ꢄ, 10 ~ 95% RH non-condensing
ꢅ0.03%/ꢄ (0 ~ 50ꢄ) RH non-condensing
TEMP. COEFFICIENT
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
VIBRATION
OPERATING ALTITUDE
SAFETY STANDARDS
2000 meters
UL60950-1, UL508, TUV EN61558-2-16, IEC60950-1 approved; Design refer to EN50178,TUV EN60950-1
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25ꢄ/ 70% RH
Standard
Test Level / Note
Class B
Class B
Class A
-------
Parameter
Conducted
Radiated
EN55032(CISPR32)
EN55032(CISPR32)
EN61000-3-2
EMC EMISSION
Harmonic Current (Note 5)
Voltage Flicker
EN55024, EN61000-6-2, EN61204-3
Parameter
SAFETY &
EN61000-3-3
EMC
(Note 6)
Test Level /Note
Standard
ESD
Level 3, 8KV air; Level 2, 4KV contact, criteria A
Level 3, criteria A
Level 3, criteria A
EN61000-4-2
EN61000-4-3
EN61000-4-4
Radiated Susceptibility
EFT/Burest
EMC IMMUNITY
Surge
Conducted
Magnetic Field
Level 4,2KV/L-N, criteria A
Level 3, criteria A
Level 4, criteria A
EN61000-4-5
EN61000-4-6
EN61000-4-8
>95% dip 0.5 periods, 30% dip 25 periods,
EN61000-4-11
Voltage Dips and interruptions
>95% interruptions 250 periods
MTBF
DIMENSION
PACKING
856.5K hrs min. MIL-HDBK-217F (25ꢄ)
70*90*54.5mm (W*H*D)
0.27Kg; 48pcs/14Kg/1.10CUFT
OTHERS
NOTE
℃
μ
μ
File Name:HDR-100-SPEC 2017-06-22