3.5 kV
Features:
HC-1
Kilovac HC-1 No Load Switching
Kilovac HC-3 Make & Break Load Switching
Widely used for RF applications
Vacuum dielectric for low leakage current
applications
Copper contacts for high current capability
Not designed for power switching
Meets requirements of MIL-R-83725
QPL version available, M83725/5-001
HC-3
Tungsten contacts for long life when power
switching
Vacuum dielectric for power switching low
current loads
Features:
Kilovac HC-5 Make Only Load Switching
Gas-filled for make only power switching
SF-6 gas filled for capacitive discharge
applications
PRODUCT SPECIFICATIONS
COIL DATA
Nominal, Volts dc
Part Number
12
26.5
115
HC-1
SPDT
C
HC-3
SPDT
C
HC-5
SPDT
C
Unit
Contact Arrangement ..........................................................
Contact Form ........................................................................
Test Voltage (dc or 60Hz) ...................................................
Rated Operating Voltage .....................................................
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Continuous Carry Current , Maximum ...............................
dc or 60 Hz .....................................................................
2.5 MHz ...........................................................................
16 MHz ............................................................................
32 MHz ............................................................................
Coil Hi-Pot (V RMS, 60 Hz) ...........................................
Contact Capacitance ............................................................
Between Open Contacts .................................................
Open Contacts to Ground ..............................................
Contact Resistance, Maximum ...........................................
Operate Time, Maximum .....................................................
Release Time, Maximum .....................................................
Shock, 11 ms 1/2 Sine ........................................................
Vibration, 10 Gs Peak .........................................................
Operating Ambient Temperature Range ............................
Mechanical Life (Operations x 106) ....................................
Weight, Nominal ..................................................................
Pickup, Volts dc, Maximum
Drop-Out, Volts dc
8
16
80
.5 - 5 1 - 10 5 - 50
80 335 6000
5
5
5
kV Peak
kV Peak
Coil Resistance (Ohms ±10%)
Ratings listed are for 25°C, sea level conditions
3.5
2.5
2
3.5
3.5
PART NUMBER SELECTION
-
-
-
-
-
-
1
/12Vdc
Sample Part No.
Model
1
3
HC-
1.5
Amps
5
25
14
9
18
8
Coil Voltage
Blank = 26.5Vdc
/12Vdc = 12Vdc
/115Vdc = 115Vdc
-
-
-
-
-
-
7
500
500
500
pF
2
2.5
-
-
-
-
Ohms
ms
0.01
6
0.02
0.50*
6
6
6
6
ms
6
G's Peak
50
50
50
Hz
oC
55-2000
55-2000
55-2000
-55 to +125 -55 to +125 -55 to +125
cycles
oz
2
1
2
1
1
1
* Contact resistance for gas-filled relays is measured at 28 Vdc, 1 amp
CII Technologies
/
P.O. Box 4422
/
Santa Barbara, CA 93140
/
ph 805.684.4560 / fax 805.684.9679 / e-mail info@kilovac.com / website www.ciitech.com
25