60W AC-DC Single Output Desktop
GS60 series
Features :
Universal AC input / Full range
3 pole AC inlet IEC320-C14
Protections: Short circuit / Overload / Over voltage/ Over temperature
Fully enclosed plastic case
Approvals: UL / CUL / PSE / TUV / BSMI / CCC / CB / FCC / CE
Class power (with earth pin)
Pass LPS
LED indicator for power on
No load power consumption<0.3W
ErP step2 compliant
NRCan compliant
Meet EISA 2007 (Energy Independence and Security Act)
2 years warranty
TUV
Rheinland
Product Safety
geprUfre
Sicherheit
(except for 48V)
SPECIFICATION
ORDER NO.
GS60A05-P1J GS60A07-P1J GS60A09-P1J GS60A12-P1J GS60A15-P1J GS60A18-P1J GS60A24-P1J GS60A48-P1J
SAFETY MODEL NO.
GS60A05
Note.2 5V
GS60A07
7.5V
GS60A09
9V
GS60A12
12V
GS60A15
15V
GS60A18
18V
GS60A24
24V
GS60A48
48V
DC VOLTAGE
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
6A
6A
6A
5A
4A
3.33A
2.5A
1.25A
0 ~ 6A
30W
0 ~ 6A
45W
0 ~ 6A
54W
0 ~ 5A
60W
0 ~ 4A
60W
0 ~ 3.33A
60W
0 ~ 2.5A
60W
0 ~ 1.25A
60W
OUTPUT
RIPPLE & NOISE (max.) Note.3 100mVp-p
VOLTAGE TOLERANCE Note.4 5.0%
100mVp-p
5.0%
100mVp-p
5.0%
100mVp-p
3.0%
100mVp-p
3.0%
150mVp-p
3.0%
180mVp-p
3.0%
240mVp-p
2.5%
LINE REGULATION
LOAD REGULATION
SETUP, RISE TIME
Note.5 1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
5.0%
5.0%
5.0%
3.0%
3.0%
3.0%
3.0%
2.5%
Note.7 1000ms, 30ms / 230VAC
1000ms, 30ms / 115VAC at full load
HOLD UP TIME (Typ.)
VOLTAGE RANGE
50ms / 230VAC
15ms / 115VAC at full load
90 ~ 264VAC 135 ~ 370VDC
47 ~ 63Hz
FREQUENCY RANGE
EFFICIENCY (Typ.)
81%
85.5%
1A / 230VAC
87.5%
88%
88.5%
88.5%
90%
92%
INPUT
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
1.4A / 115VAC
65A / 230VAC
0.75mA / 240VAC
105 ~ 150% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
5.25 ~ 6.75V 7.88 ~ 10.13V 9.45 ~ 12.15V 12.6 ~ 16.2V 15.75 ~ 20.25V 18.9 ~ 24.3V 25.2 ~ 32.4V 50.4 ~ 64.8V
OVERLOAD
PROTECTION
OVER VOLTAGE
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover
RTH2 > 70
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
-40 ~ +85 , 10 ~ 95% RH
ENVIRONMENT
0.03% / (0 ~ 50
)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, TUV EN60950-1, BSMI CNS14336, CCC GB4943, J60950-1(except for 48V) approved
I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
SAFETY STANDARDS
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
EMC EMISSION
SAFETY &
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH
EMC
(Note. 6)
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254 class B, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
EMC IMMUNITY
MTBF
711Khrs min. MIL-HDBK-217F(25
125*50*31.5mm (L*W*H)
)
DIMENSION
OTHERS
0.305Kg; 40pcs/13.02Kg/1.05CUFT
PACKING
PLUG
Standard type P1J: 2.1 * 5.5 * 11mm, tuning fork type, center positive for stock ; Other type available by customer requested
See page 2 ; Other type available by customer requested
CONNECTOR
CABLE
1. All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
NOTE
5. Line regulation is measured from low line to high line at rated load.
6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
EMC directives.
7. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
File Name:GS60-SPEC 2012-03-06