Continued from the preceding page.
tTemperature Characteristics
Temperature Characteristic Codes
Temperature Characteristics
Operating
Temperature Range
Reference
Temperature
Temperature
Range
Capacitance Change or
Temperature Coefficient
Code
Public STD Code
JIS
1X
2C
2P
2R
2S
2T
3C
3P
3R
3S
3T
3U
4C
5C
5G
6C
6P
6R
6S
6T
7U
B1
B3
C7
C8
D7
D8
E7
F1
F5
L8
R1
R3
R6
R7
R9
SL *1
CH *1
PH *1
RH *1
SH *1
TH *1
CJ *1
PJ *1
RJ *1
SJ *1
TJ *1
UJ *1
CK *1
C0G *1
X8G *1
C0H *1
P2H *1
R2H *1
S2H *1
T2H *1
U2J *1
B *2
20°C
20°C
20°C
20°C
20°C
20°C
20°C
20°C
20°C
20°C
20°C
20°C
20°C
25°C
25°C
25°C
25°C
25°C
25°C
25°C
25°C
20°C
20°C
25°C
25°C
25°C
25°C
25°C
20°C
25°C
25°C
20°C
20°C
25°C
25°C
25°C
20 to 85°C
20 to 125°C
20 to 85°C
+350 to -1000ppm/°C
0±60ppm/°C
-150±60ppm/°C
-220±60ppm/°C
-330±60ppm/°C
-470±60ppm/°C
0±120ppm/°C
-150±120ppm/°C
-220±120ppm/°C
-330±120ppm/°C
-470±120ppm/°C
-750±120ppm/°C
0±250ppm/°C
0±30ppm/°C
0±30ppm/°C
0±60ppm/°C
-150±60ppm/°C
-220±60ppm/°C
-330±60ppm/°C
-470±60ppm/°C
-750±120ppm/°C
±10%
-55 to 125°C
-55 to 125°C
-25 to 85°C
-25 to 85°C
-25 to 85°C
-25 to 85°C
-55 to 125°C
-25 to 85°C
-25 to 85°C
-25 to 85°C
-25 to 85°C
-25 to 85°C
-55 to 125°C
-55 to 125°C
-55 to 150°C
-55 to 125°C
-55 to 125°C
-55 to 125°C
-55 to 125°C
-55 to 125°C
-55 to 125°C
-25 to 85°C
-25 to 85°C
-55 to 125°C
-55 to 105°C
-55 to 125°C
-55 to 105°C
-55 to 125°C
-25 to 85°C
-30 to 85°C
-55 to 150°C
-55 to 125°C
-55 to 125°C
-55 to 85°C
-55 to 125°C
-55 to 150°C
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
JIS
EIA
EIA
EIA
EIA
EIA
EIA
EIA
EIA
JIS
JIS
EIA
EIA
EIA
EIA
EIA
JIS
EIA
*3
20 to 85°C
20 to 85°C
20 to 85°C
20 to 125°C
20 to 85°C
20 to 85°C
20 to 85°C
20 to 85°C
20 to 85°C
20 to 125°C
25 to 125°C
25 to 150°C
25 to 125°C
25 to 85°C
25 to 85°C
25 to 85°C
25 to 85°C
25 to 125°C *6
-25 to 85°C
-25 to 85°C
-55 to 125°C
-55 to 105°C
-55 to 125°C
-55 to 105°C
-55 to 125°C
-25 to 85°C
-30 to 85°C
-55 to 150°C
-55 to 125°C
-55 to 125°C
-55 to 85°C
-55 to 125°C
-55 to 150°C
B
±10%
X7S
±22%
X6S
±22%
X7T
+22, -33%
X6T
+22, -33%
X7U
+22, -56%
F *2
+30, -80%
Y5V
+22, -82%
X8L
+15, -40%
R *2
JIS
JIS
EIA
EIA
EIA
±15%
R
±15%
X5R
±15%
X7R
±15%
X8R
±15%
±10% *4
W0
-
-
25°C
-55 to 125°C
-55 to 125°C
+22, -33% *5
*1 Please refer to table for Capacitance Change under reference temperature.
*2 Capacitance change is specified with 50% rated voltage applied.
*3 Murata Temperature Characteristic Code.
*4 Apply DC350V bias.
*5 No DC bias.
*6 Rated Voltage 100Vdc max : 25 to 85°C
Continued on the following page.