GenesysTM 3U 10kW Specifications
10kW
1.0 MODEL
1.Rated Output Voltage
GEN
VDC
ADC
kW
7.5-1000 10-1000 12.5-800 20-500 25-400 30-333 40-250 50-200 60-167 80-125 100-100 125-80
X
X
X
X
X
X
7.5
1000
7.5
10
12.5
800
10.0
20
500
10.0
25
400
10.0
30
333
10.0
40
250
10.0
83
50
200
10.0
60
167
10.0
80
125
10.0
100
100
10.0
125
80
10.0
2.Rated Output Current
3.Rated Output Power
1000
10.0
4.Efficiency (min) at low AC line, 100% Rated Load
%
77
Contact Factory for other models
1.1 CONSTANT VOLTAGE MODE (CV)
1. Max. Line Reg (0.1% - Vor ≤ 30V; 0.05% - 30V < Vor <
600V; 0.05% - 600V < Vor < 1500V)
2. Max. Load Reg (0.1% for Vor ≤ 30V; 0.05% for 30V < Vor
< 600V; 0.1% for 600V < Vor < 1500V)
mV
mV
7.5
7.5
10
10
12.5
12.5
20
20
25
25
30
30
20
20
25
25
30
30
40
40
50
50
62.5
62.5
X
X
3. Output Ripple, rms (5Hz~1MHz), CV mode; (*1)
4. Output Noise, p-p (20MHz), CV mode; (*1)
5.Remote Sense Compensation / Wire
6. Temperature Stability
mV
mV
V
20
60
1
20
60
1
20
60
1
20
60
1
20
60
1
20
60
1.5
20
60
2
20
75
3
20
75
3
25
100
4
25
100
5
25
125
5
X
X
X
X
X
X
X
X
---
± 0.05% of Vo(rated) over 8 hours after 30 minute warm up (constant Line, Load & Temperature)
7. Temperature Coefficient
ppm / °C ± 200 (± 0.02% of Vo(rated)) / °C
8. Up-Prog. Response Time, 0 ~ Vomax, full-load
9. Up-Prog. Response Time, 0~Vomax, no-load
10. Transient Response Time (CV mode); (*2), (*3)
ms
ms
ms
100
50
Less than 3
1.2 CONSTANT CURRENT MODE (CC)
1. Max. Line Reg. (0.1% - Ior > 333A; 0.050% - 17A < Ior <
mA
mA
1000
1000
800
500
400
333
125
100
83.5
62.5
50
40
X
X
333A; 0.15% - Ior < 17A)
2. Max. Load Reg (0.1% - Ior > 333A; 0.075% - 17A < Ior <
333A; 0.2% - Ior < 17A)
3. Output Ripple, rms (5Hz~1MHz), CC mode
4. Temperature Stability
5. Temperature Coefficient
1000
5300
1000
4000
800
500
400
640
333
444
188
250
150
160
125
67
94
50
75
40
60
32
mA
---
ppm/°C
2560
1000
X
X
X
± 0.05% of Io(rated) over 8 hours, after 30 minute warm up (constant Line, Load & Temperature)
± 300 (± 0.03% of Io(rated)) / °C
1.3 PROTECTIVE FUNCTIONS
1. OCP
2. OCP type
3. Foldback Protection (FOLD)
4. Foldback Response Time
5. OVP type
%
---
---
s
---
%
0 ~ 100
Constant current
X
X
X
X
X
X
Output shutdown; Manual reset by front panel OUT button or Digital communication, user-selectable
Less than 1 (Min = 0.25 / Max = 25 / Default = 0.25); Settable via “FBD” command
Inverter shut-down; Manual reset by AC On/Off recycle, OUT button, Remote Analog or Digital commuincation
± 5% of Vo(rated)
6. OVP Programming Accuracy
5% to 105% of Vo(rated) for Vor < 600V; 10% to 105% of Vo(rated) for 600V < Vor < 1500V
Shall always be greater than 105% of Vo(setting); Default = 105% of Vo(rated)
Less than 10 (for Output to begin to drop) for Vor < 600V
Less than 2.0 (for Output to begin to drop) for 600V < Vor < 1500V
7. OVP Trip Point
V
X
8. OVP Response Time
ms
X
9. Max. OVP Reset Time
10. Over-Temperature Protection (OTP)
11. Phase-Loss Protection
s
---
---
7 (from AC On/Off switch turn On)
Shut down if internal temperature exceeds safe operating levels (Latched: Safe / Unlatched: Auto)
Yes, power supply shutdown (Latched: Safe-Start / Unlatched: Auto-Restart)
X
X
X
1.4 REMOTE ANALOG CONTROLS & SIGNALS
1. Vout Voltage Programming
2. Iout Voltage Programming
3. Vout Resistor Programming
4. Iout Resistor Programming
5. Shut-Off (SO) Control (rear panel)
6. Output Current Monitor
7. Output Voltage Monitor
8. Power Supply OK (PS_OK) Signal
9. CV/CC Signal
0~100%, 0 ~ 5V or 0 ~ 10V, user-selectable., Accuracy & Linearity: ±1% of Vo(rated)
0~100%, 0 ~ 5V or 0 ~ 10V, user-selectable, Accuracy & Linearity: ± 1% of Io(rated)
0~100%, 0 ~ 5/10kohm full-scale, user-selectable, Accuracy & Linearity: ± 1% of Vo(rated)
0~100%, 0 ~ 5/10kohm full-scale, user-selectable, Accuracy & Linearity: ± 1% of Io(rated)
By Voltage: 0.6V = DIS, 2-15V = ENA (default) or by Dry Contact: Open = ENA, Short = DIS (user-selectable logic)
0 ~ 5V or 0 ~ 10V, Accuracy: ± 1% of Io(rated), user-selectable
0 ~ 5V or 0 ~ 10V, Accuracy: ± 1% of Vo(rated), user-selectable
Yes. TTL High = OK, 0V = Fail (500ohm series impedance)
CV: TTL High (4 ~ 5V), Max source current = 10mA; CC: TTL Low (0 ~ 0.4V), Max sink current = 10mA
Dry contact; Open = OFF, Short = ON; Maximum voltage across Enable/Disable contacts = 6V
Selects Remote or Local operation by voltage: 0 ~ 0.6V = Local / 2 ~ 15V = Remote
Signals operating mode; Open collector: Local = Open (Max voltage = 30V), Remote = On (Max sink current = 10mA)
X
X
X
X
X
X
X
X
X
X
X
X
10. Enable/Disable
11. Remote/Local Selection
12. Remote/Local Signal
1.5 FRONT PANEL
1.Control Functions
X
X
X
X
X
X
X
X
X
X
Vout/ Iout manual adjust by separate encoders (COARSE and FINE adjustment selectable)
OVP/UVL manual adjust by VOLTAGE Adjust encoder, Front Panel Lock/Unlock
Address selection by VOLTAGE Adjust encoder. # of Addresses = 31
AC ON/OFF, Output On/Off, Restart Modes (Auto/Safe), Foldback Control (CV to CC), Go-to-Local
RS-232/RS-485, LAN, IEEE (IEMD) and USB selection by rear panel DIP-switch
Baud rate selection (RS-232/RS-485 only): 1200, 2400, 4800, 9600 and 19,200 (by CURRENT Adjust encoder)
Advanced Parallel Master/Slave: Hx = Master unit, where x = # of Slave units (0 to 4), S = Slave unit(s)
Voltage: 4 digits, Accuracy: ± 0.5% of Vo(rated) ±1 count
2.Display
Current: 4 digits, Accuracy: ± 0.5% of Io(rated) ±1 count
VOLTAGE meter displays voltage at power supply (Local sense) or at load (Remote sense)
3.Indications
Green LED’s: PREVIEW, FOLD, REM/LOCAL, OUT ON/OFF, CV/CC, FINE
Red LED: ALARM (OVP, OTP, FOLD, AC FAIL, ENA, SO)
X
1.6 DIGITAL PROGRAMMING & READBACK
1. Vout Programming Accuracy
2. Iout Programming Accuracy
3. Vout Programming Resolution
4. Iout Programming Resolution
5. Vout Readback Accuracy
6. Iout Readback Accuracy
7. Vout Readback Resolution
8. Iout Readback Resolution
9. OV Response Time
± 0.5% of Vo(rated)
X
X
X
X
X
X
X
X
X
X
± 0.5% of Io(rated) for units with Io < 187.5A; ± 0.7% of Io(rated) for Io ≥187.5A
0.02% of Vo(rated)
0.04% of Io(rated)
± (0.1% of Vo(actual) + 0.2% of Vo(rated))
± (0.1% of Io(actual) + 0.4% of Io(rated))
0.02% of Vo(rated)
0.02% of Io(rated)
20ms maximum (between Vout exceeding IEEE Limit and supply Inhibit turning On)
Set OVP/UVL limits; Set Local/Remote, Operating parameters and Status, Get Identity
10. Other Functions
*1 Ripple and Noise at Vo(rated) and rated Load, Ta = +25C and nominal AC Input per EIJ R900A.
*2. Time for the Output voltage to recover within 2% of rating for a load current change of 50~100% or 100-50% of Io(rated).
*3. Operating with a load that continuously pulses the current (or voltage) can reduce the operating life of the Power Supply. Please contact TDK-Lambda Sales/Technical Support to discuss the
application in detail.
All specifications subject to change without notice.