■ Specifications and Test Methods
No Item
Specification
Test Method(Ref. Standard:AEC-Q200)
Solder the capacitor on the test substrate
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
+25℃ to +65℃
Appearance
No defects or abnormalities.
Within +/-10%
DF≦0.25
Mounting method
Pre-treatment
5 Moisture Resistance
Capacitance Change
Q or D.F.
I.R.(Room Temp.)
More than 25Ω・F
Test Temperature
Test Humidity
80%RH to 98%RH
Test Time
Apply the 24h treatment shown below, 10 consecutive times.
Temperature and Humidity cycle
Post-treatment
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-12.5%
DF≦0.25
Mounting method
Pre-treatment
Solder the capacitor on the test substrate
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
6 Biased Humidity
I.R.(Room Temp.)
More than 5Ω・F
Test Temperature
Test Humidity
Test Time
85+/-3℃
80%RH to 85%RH
1000+/-12h
Test Voltage
The rated voltage and 1.3+0.2/-0Vdc (add 6.8kΩ resister)
Charge/discharge current 50mA max.
Post-treatment
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
Appearance
Capacitance Change
Q or D.F.
No defects or abnormalities.
Within +/-12.5%
DF≦0.25
Mounting method
Pre-treatment
Solder the capacitor on the test substrate
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
7 Operational Life
I.R.(Room Temp.)
More than 5Ω・F
Test Temperature
Test Time
Maximum Operating Temperature +/-3℃
1000+/-12h
Test Voltage
150% of the rated voltage
Charge/discharge current 50mA max.
Post-treatment
Heat treatment:Perform a heat treatment at 150+0/-10°C for 1hour and then let sit for 24+/-2hours
at room temperature, then measure.
GCJ32ER91C685KE01-01A
3