AEC-Q200 Murata Standard Specification and Test Methods  
Specification.  
High Dielectric Type  
No  
7
AEC-Q200 Test Item  
Operational Life  
AEC-Q200 Test Method  
Temperature  
Compensating Type  
The measured and observed characteristics should satisfy the  
specifications in the following table.  
Fix the capacitor to the supporting jig in the same manner and  
under the same conditions as No.16.  
Appearance  
Capacitance  
Change  
No marking defects  
Apply 200% of the rated voltage for 1000±12 hours at 125±3(for  
Δ C/R7), 150±3(for 5G/L8/R9).  
Within ±3.0% or ±0.30pF  
(Whichever is larger)  
30pFmin. : Q350  
R7/L8/R9: Within ±12.5%  
R7/L8 : 0.05 max.  
Set for 24±2 hours at room temperature, then measure.  
The charge/discharge current is less than 50mA.  
Q/D.F.  
10pF and over, 30pF and below: R9 : 0.075max.  
Q275+5C/2  
Initial measurement for high dielectric constant type.  
Apply 200% of the rated DC voltage for one hour at the maximum  
operating temperature ±3. Remove and set for 24±2 hours at  
room temperature. Perform initial measurement.  
10pFmax.: Q 200+10C  
C: Nominal Capacitance(pF)  
More than 1,000MΩ or 50Ω F  
(Whichever is smaller)  
I.R.  
8
9
External Visual  
No defects or abnormalities  
Visual inspection  
Using calipers  
Physical Dimension  
Within the specified dimensions  
10 Resistance to Appearance  
No marking defects  
Per MIL-STD-202 Method 215  
Solvents  
Capacitance  
Within the specified tolerance  
Solvent 1 : 1 part (by volume) of isopropyl alcohol  
3 parts (by volume) of mineral spirits  
Change  
Q/D.F.  
30pFmin. : Q1000  
R7/L8 : W.V.: 25Vmin.: 0.025 max.  
W.V.: 16V : 0.035 max.  
R9 : 0.075max.  
Solvent 2 : Terpene defluxer  
30pFmax.: Q 400+20C  
C: Nominal Capacitance(pF)  
Solvent 3 : 42 parts (by volume) of water  
1part (by volume) of propylene glycol monomethyl ether  
1 part (by volume) of monoethanolamine  
I.R.  
More than 10,000MΩ or 500Ω F  
(Whichever is smaller)  
11 Mechanical  
Shock  
Appearance  
Capacitance  
Change  
No marking defects  
Fix the capacitor to the test jig in the same manner and under the  
same conditions as No.16.Three shocks in each direction should be  
applied along 3 mutually perpendicular axes of the test specimen  
(18 shocks).  
Within the specified tolerance  
Q/D.F.  
30pFmin. : Q1000  
R7/L8 : W.V.: 25Vmin.: 0.025 max.  
W.V.: 16V : 0.035 max.  
R9 : 0.075max.  
30pFmax.: Q 400+20C  
C: Nominal Capacitance(pF)  
The specified test pulse should be Half-sine and should have a  
duration :0.5ms, peak value:1500g and velocity change: 4.7m/s.  
I.R.  
More than 10,000MΩ or 500Ω F  
(Whichever is smaller)  
12 Vibration  
Appearance  
Capacitance  
Change  
No defects or abnormalities  
Within the specified tolerance  
Fix the capacitor to the test jig in the same manner and under the  
same conditions as No.16. The capacitor should be subjected to a  
simple harmonic motion having a total amplitude of 1.5mm, the  
frequency being varied uniformly between the approximate limits of  
10 and 2000Hz. The frequency range, from 10 to 2000Hz and  
return to 10Hz, should be traversed in approximately 20 minutes.  
This motion should be applied for 12 cycle in each 3 mutually  
perpendicular directions  
Q/D.F.  
30pFmin. : Q1000  
R7/L8 : W.V.: 25Vmin.: 0.025 max.  
W.V.: 16V : 0.035 max.  
R9 : 0.075max.  
30pFmax.: Q 400+20C  
C: Nominal Capacitance(pF)  
I.R.  
More than 10,000MΩ or 500Ω F  
(Whichever is smaller)  
13 Thermal Shock  
The measured and observed characteristics should satisfy the  
specifications in the following table.  
Fix the capacitor to the supporting jig in the same manner and  
under the same conditions as No.16. Perform the 300 cycles  
according to the two heat treatments listed in the following  
table(Maximum transfer time is 20 seconds). Set for 24±2 hours at  
room temperature, then measure  
Appearance  
Capacitance  
Change  
No marking defects  
Within ±2.5% or ±0.25pF  
(Whichever is larger)  
R7/L8/R9: Within ±10.0%  
Q/D.F.  
30pFmin. : Q1000  
R7/L8 : W.V.: 25Vmin.: 0.025 max.  
GCG21BL81H104K: 0.03 max.  
W.V.: 16V : 0.035 max.  
Step  
1
2
30pFmax.: Q 400+20C  
C: Nominal Capacitance(pF)  
125+3/-0(forΔC/R7)  
150+3/-0for 5G/L8/R9)  
Temp.(℃)  
-55+0/-3  
Time  
(min.)  
R9 : 0.075max  
15±3  
15±3  
I.R.  
More than 10,000MΩ or 500ΩF  
(Whichever is smaller)  
Initial measurement for high dielectric constant type  
Perform a heat treatment at 150+0/-10 ℃ꢀfor one hour and then set  
for 24±2 hours at room temperature.  
Perform the initial measurement.  
JEMCGS-01499C  
3

与GCG1555C1H1R6BA01#相关器件

型号 品牌 描述 获取价格 数据表
GCG1555C1H1R6CA01# MURATA 汽车[动力总成 / 安全设备],汽车[信息娱乐 / 舒适设备],植入式以外的医疗器械设备

获取价格

GCG1555C1H1R6DA01# MURATA 汽车[动力总成 / 安全设备],汽车[信息娱乐 / 舒适设备],植入式以外的医疗器械设备

获取价格

GCG1555C1H1R7BA01# MURATA 汽车[动力总成 / 安全设备],汽车[信息娱乐 / 舒适设备],植入式以外的医疗器械设备

获取价格

GCG1555C1H1R7CA01# MURATA 汽车[动力总成 / 安全设备],汽车[信息娱乐 / 舒适设备],植入式以外的医疗器械设备

获取价格

GCG1555C1H1R7DA01# MURATA 汽车[动力总成 / 安全设备],汽车[信息娱乐 / 舒适设备],植入式以外的医疗器械设备

获取价格

GCG1555C1H1R8BA01# MURATA 汽车[动力总成 / 安全设备],汽车[信息娱乐 / 舒适设备],植入式以外的医疗器械设备

获取价格