■AEC-Q200 Murata Standard Specification and Test Methods
No
AEC-Q200 Test Item
Specification.
AEC-Q200 Test Method
18 Board Flex
Appearance
No marking defects
Within +/-10.0%
Solder the capacitor on the test substrate(glass epoxy board)
shown in Fig1.
Capacitance
Change
Then apply a force in the direction shown in Fig 2 for 60s.
The soldering should be done by the reflow method and should be
conducted with care so that the soldering is uniform and free of defects
such as heat shock.
D.F.
Within the specified initial value.
Within the specified initial value.
Type
GCE18
GCE21
a
b
c
I.R.ꢀ25℃
0.6
0.8
2.2
3.0
0.9
1.3
(in mm)
50 min.
b
Land
20
f4.5
Pressurizing
speed:1.0mm/s
Pressurize
R4
a
100
Flexure:5
Capacitance meter
45 45
t : 1.6mm
Fig.
Fig.2
19 Terminal
Strength
Appearance
Capacitance
D.F.
No marking defects
Solder the capacitor on the test substrate(glass epoxy board)
shown in Fig3.
Then apply 18N force in parallel with the test jig for 60s.
The soldering should be done either with an iron or using the reflow
method and should be conducted with care so that the soldering is
uniform and free of defects such as heat shock
Within the specified initial value.
Within the specified initial value.
Within the specified initial value.
Type
GCE18
GCE21
a
b
c
1.0
1.2
3.0
4.0
1.2
1.65
I.R.ꢀ25℃
c
(in mm)
t: 1.6mm
Solder resist
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀFig.3
Baked electrode or
Copper foil
20 Beam Load Test
Destruction value should be exceed following one.
< Chip L dimension : 2.5mm max. >
ꢀꢀ Chip thickness > 0.5mm rank : 20N
ꢀ
Place the capacitor in the beam load fixture as Fig 4.
Apply a force.
< Chip Length : 2.5mm max. >
Iron Board
Fig.4
Speed supplied the Stress Load : 0.5mm/s
21 Capacitance Temperature
Characteristics
R7 : Within +/-15%
The capacitance change should be measured after 5 minutes
ꢀꢀꢀꢀꢀꢀꢀ(-55℃ to +125℃)
at each specified temperature stage.
Capacitance value as a reference is the value in step 3.
Step
Temperature(C)
Reference Temp.+/-2
Min. Operating Temp.+/-3
Reference Temp.+/-2
Max. Operating Temp.+/-3
Reference Temp.+/-2
1
2
3
4
5
・ Initial measurement
Perform a heat treatment at 150+0/-10 ℃for 1h and then sit
for 24+/-2h at room temperature.
Perform the initial measurement.
JEMCGS-02082A
5