Surface-mounting High-frequency Relay
■Tube Packing and Tape Packing
2. Reel Dimensions
(1) Tube Packing
±1
33.5
• Relays in tube packing are arranged so that the orientation
mark of each Relay in on the left side.
Be sure not to make mistakes in Relay orientation when
mounting the Relay to the PCB.
±1
37.5
±0.2
13
dia.
±0.8
21
dia
±0.5
2
A
Operation of Relays
Stopper (gray)
Stopper (green)
330 80
R1
Enlarged view of A
Tube length: 530 mm (stopper not included)
No. of Relays per tube: 25 pcs
3. Carrier Tape Dimensions
(2) Tape Packing (Surface-mounting Terminal Models)
• When ordering Relays in tape packing, add the prefix “-TR” to
the model number, otherwise the Relays in tube packing will
be provided.
±0.1
10
±0.1
16
4
±0.1
1.5+0.1 dia.
±0.1
±0.1
1.75
14.2
±0.1
±0.05
2
0.5
0
±0.1
±0.1
±0.1
20.6
28.4
22.6
Relays per Reel: 300 pcs
±0.3
32
Minimum packing unit: 1 Reel (300 pcs)
1. Direction of Relay Insertion
Pulling direction
5°MAX
±0.1
10.2
1.5+0.1
A
0
1.7+0.15
0
G
6
Z
Orientation mark
±0.1
4
5°MAX
0.2
Top tape
(cover tape)
R0.75
Enlarged view of A
Pulling
direction
Note. The radius of the unmarked corner is 0.3 mm.
Carrier tape
Emboss
tape
■Recommended Soldering Method
●Temperature Conditions for IRS Method
• When using reflow soldering, ensure that the Relay terminals
and the top of the case stay below the following curve. Check
that these conditions are actually satisfied before soldering the
terminals.
• The thickness of cream solder to be applied should be
between 150 and 200 μm on OMRON’s recommended PCB
pattern.
Correct Soldering
Incorrect Soldering
Relay
T4
T3
Terminal
Land
PCB
Heel fillet
is formed
T2
T1
Solder
Insufficient amount of solder
Excessive amount of solder
Check the soldering in the actual mounting conditions before
use.
t
2
t
1
Time
Soldering
Preheating
Preheating
(T1→T2, t1)
Soldering
(T3, t2)
Maximum peak
(T4)
Measured part
150→180°C,
230°C min,
30 s max.
Terminals
250°C max.
255°C max.
120 s max.
Top of case
−
−
• Do not quench the terminals after mounting. Clean the Relay
using alcohol or water no hotter than 40°C max.
11