Characteristics
Item
Non-latching
models
Single coil latching
models
Dual coil latching
models
G6Z-1P(E), G6Z-1F(E)
G6ZU-1P(E), G6ZU-1F(E)
G6ZK-1P(E), G6ZK-1F(E)
Contact resistance (See note 2)
Operating (set) time (See note 3)
Release (reset) time (See note 3)
Set/reset time
100 mΩ max.
10 ms max. (approx. 3.5 ms) 10 ms max. (approx. 2.5 ms)
10 ms max. (approx 2.5 ms)
---
12 ms
Insulation resistance (See note 4)
100 MΩ min. (at 500 VDC)
Dielectric strength
Coil and contacts
1,000 VAC, 50/60 Hz for 1 min.
500 VAC, 50/60 Hz for 1 min.
Coil and ground,
contacts and ground
Contacts of same
polarity
500 VAC, 50/60 Hz for 1 min.
Vibration resistance
Shock resistance
Mechanical durability
10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction durability 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
1,000 m/s2
500 m/s2
Mechanical durability
Malfunction durability
Mechanical
Service life
1,000,000 operations min. (at 36,000 operations/hour)
Electrical
300,000 operations min. (30 VAC, 10 mA/30 VDC, 10 mA), 100,000 operations min.
(900 MHz, 10 W) at a switching frequency of 1,800 operations/hour
Ambient temperature
Ambient humidity
Weight
Operating: -40°C to 70°C (with no icing or condensation)
Operating: 5% to 85% RH
Approx. 2.8 g
Note: 1. The above values are initial values.
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
3. Values in parentheses are typical values.
4. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the
dielectric strength.
Engineering Data
Ambient Temperature vs.
Maximum Voltage
Ambient Temperature vs. Must
Operate or Must Release Voltage
Shock Malfunction
Y
100
250
200
150
100
50
1,000
Max. estimated value
Energized
Sample: G6Z-1P 5 VDC
90 Number of relays: 5
800
600
400
200
max.
Not
80
70
60
50
40
30
20
10
0
X
1,000
Z
energized
1,000
G6Z
G6ZU
avg.
min.
200
400
600
800
G6ZK
max.
1,000
Z'
1,000
X'
avg.
Shock direction
X
min.
X'
Unit:
m/s2
Y
1,000
Z
Sample: G6Z-1P-A 50 Ω
Must operate voltage
Must release voltage
Y'
5 VDC
Z'
Number of relays: 5
0
Y'
−60 −40 −20
0
20
40
60
80 100
−40
−20
0
20
40
60
80 100
Ambient temperature (°C)
Ambient temperature (°C)
Conditions: Shock is applied in X, Y, and
Z
directions three times each with and
without energizing the Relays to check
for contact malfunctions.
114
High-frequency Relay G6Z