■ Characteristics
Type
Contact resistance (See note 2)
Operate (set) time
Non-latching
Latching
50 mΩ max.
5 ms. max. (mean value approx 2.4 ms)
5 ms. max. (mean value approx. 1.1 ms)
36,000 operations/hour
5 ms. max. (mean value approx. 2.0 ms)
5 ms. max. (mean value approx. 1.8 ms)
Release (reset) time
Operatingfrequency Mechanical
(max.)
Electrical
18,000 operations/hour (under rated load)
1,000 mΩ min. (at 250 VDC)
Insulation resistance (See note 3)
Dielectric strength
Standard
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts (See note 4)
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (See note 4)
500 VAC, 50/60 Hz for 1 minute between contacts of same pole (See note 5)
Set and reset coils
--
100 VAC, 50/60 Hz for 1 minute
Impulse Withstand Voltage (See notes 4 & 5) 1,500 V (10 x 160 μs) between contacts of the same polarity (conforms to FCC Part 68)
Vibration
Mechanical durability 10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
Malfunction durability 10 to 55 Hz; 1.50 mm (0.06 in) double amplitude
1,000 m/s2 (approx. 100 G)
300 m/s2 (approx. 30 G
Shock
Mechanical durability
Malfunction durability
Ambient temperature
Humidity
-40 to 70°C (-40 to 158°F) with no icing
5% to 85% RH
Service life
Mechanical
Electrical
50 million operations min.
at 36,000 operations/hour
50 million operations min.
at 36,000 operations/hour
100,000 operations min. (at 1,800 operations/hr) See “Characteristic Data”
Approx. 3 g (0.11 oz)
Weight
Note: 1. Data shown are of initial value.
2. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method
3. The insulation resistance was measured with a 250-VDC megohmmeter applied to the same parts as those used for checking
the dielectric strength (except between the set and reset coil).
4. Models with FC suffix: 1,200 VAC, 50/60 Hz for 1 min, impulse withstand voltage of 1,500 V (10 x 160 μs)
5. Models with FC suffix: 750 VAC, 50/60 Hz for 1 min, impulse withstand voltage of 1,500 V (10 x 160 μs)
■ Characteristic Data
Maximum Switching Capacity
Electrical Service Life
Ambient Temperature vs.
Maximum Coil Voltage
10,000
30-VDC inductiveload
(L/R = 7 ms)
5,000
200 mW
30-VDC
resistive
DC resistive
load
load
30-VAC
resistive
load
1,000
500
AC resistive
load
280 mW
DC inductive
load (L/R = 7
ms)
100
50
AC inductive load
(cosf = 0.4)
30-VAC inductive
load (cosf = 0.4)
Rated operating voltage (V)
Rated operating current (A)
Ambient temperature (°C)
Note: The maximum coil voltage refers to
the maximum value in a varying
range of operating power voltage,
not a continuous voltage.
Low Signal Relay G5A
33