G4Q
■ Characteristics
Contact resistance (See note 2.)
Operate time (See note 3.)
Max. operating frequency
50 mΩ max.
60 ms max.
Mechanical: 1,200 operations/hr
Electrical:
1,200 operations/hr (under rated load)
Insulation resistance (See note 4.)
Dielectric strength
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min between coil and contact (1,000 VAC, 50/60 Hz for 1 min between con-
tacts of same polarity) (2,000 VAC between contacts of different polarities)
Vibration resistance
Shock resistance
Destruction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Destruction: 500 m/s2
Malfunction: 100 m/s2
Endurance
Mechanical:
Electrical:
5,000,000 operations min. (at operating frequency of 1,200 operations/hr)
500,000 operations min. (under rated load and at operating frequency of
1,200 operations/hr) (See note 5.)
Error rate (See note 6.)
Ambient temperature
Ambient humidity
Weight
1 A at 5 VDC (0.1 A at 5 VDC)
Operating:
Operating:
–10°C to 55°C (with no icing or no condensation)
5% to 85%
Open model: Approx. 240 g; cased model: Approx. 340 g
Note: 1. The data shown above are initial values.
2. The contact resistance was measured with 0.1 A at 5 VDC using the voltage drop method.
3. The operate time was measured with the rated voltage imposed with any contact bounce ignored at an ambient temperature of 23°C.
4. The insulation resistance was measured with a 500-VDC megger applied to the same places as those used for checking the dielectric
strength.
5. The electrical endurance was measured at an ambient temperature of 23°C.
6. This value was measured at a switching frequency of 60 operations per minute. The value in parentheses is for the cased model.
Engineering Data
Electrical Endurance
Maximum Switching Power
10,000
7,000
5,000
DC resistive load
AC resistive load
220 VAC resistive load
24 VDC resistive load
3,000
AC inductive load
(cosφ = 0.4)
24VDC inductive load
L/R = 7 ms
1,000
700
500
DC inductive load
L/R = 7 ms
300
100
70
50
220 VAC inductive load
(cosφ = 0.4)
30
Switching current (A)
Switching voltage (V)
3